The compressor and outdoor fan keep running and the indoor fan runs at low speed. After running for
30 minutes, AC will turn to auto mode with 24
℃
setting temperature.
Forced auto mode:
The action of forced auto mode is the same as normal auto mode with 24
℃
setting temperature.
When AC receives signals, such as switch on, switch off, timer on, timer off, mode setting, fan
speed setting, sleeping mode setting, follow me setting, it will quit the forced operation.
The forced operation function cannot be memorized if power off.
8.4.7 Timer function
10.4.7.1 Timing range is 24 hours.
10.4.7.2 Timer on. The machine will turn on automatically when reaching the setting time.
10.4.7.3 Timer off. The machine will turn off automatically when reaching the setting time.
10.4.7.4 Timer on/off. The machine will turn on automatically when reaching the setting “on” time,
and then turn off automatically when reaching the setting “off” time.
10.4.7.5 Timer off/on. The machine will turn off automatically when reaching the setting “off” time,
and then turn on automatically when reaching the setting “on” time.
10.4.7.6 The timer function will not change the AC current operation mode. Suppose AC is off now, it
will not start up firstly after setting the “timer off” function. And when reaching the setting time, the timer
LED will be off and the AC running mode has not been changed.
10.4.7.7 The setting time is relative time.
10.4.7.8 The AC will quit the timer function when it has malfunction.
10.4.8 Sleep function mode
10.4.8.1 Operation time in sleep mode is 7 hours. After 7 hours the AC quits this mode and turns off.
10.4.8.2. Operation process in sleep mode is as follow:
When cooling, the setting temperature rises 1
℃
(be lower than 30
℃
) every one hour, 2 hours later the
setting temperature stops rising and indoor fan is fixed as low speed.
When heating, the setting temperature decreases 1
℃
(be higher than 17
℃
) every one hour, 2 hours
later the setting temperature stops rising and indoor fan is fixed as low speed. (Anti-cold wind function
has the priority)
10.4.8.3 Timer setting is available
10.4.8.4 When user uses timer off function in sleep mode (or sleep function in timer off mode), if the