DM12-01.01.09en
Oasis
On-off
Service manual
11
Net/Gross
weight
Kg
12.5 / 15.5
16 / 20
Outdoor
fan
motor
Model
YDK55-6H
YDK100-6D(B)
Brand
Welling
Welling
Input
W
106
177
Capacitor
uF
3.0
5.0
Speed
r/min
865 / -- / --
875 / -- / --
Outdoor
coil
a.Number
of
rows
2
2
b.Tube
pitch(a)x
row
pitch(b)
mm
21x13.37
21x13.37
c.Fin
spacing
mm
1.4
1.4
d.Fin
type
(code)
Hydrophilic aluminium
Hydrophilic aluminium
e.Tube
outside
dia.and
type
mm
7,innergroove tube
7,innergroove tube
f.Coil
length
x
height
x
width
mm
785x651x26.74
785x651x26.74
g.Number
of
circuits
4
4
Outdoor
air
flow
m
3
/h
2500
2700
Outdoor
noise
level
dB(A)
57
60
Outdoor
unit
Dimension(W*D*H)
mm
845x320x700
845x320x700
Packing
(W*D*H)
mm
965x395x755
965x395x755
Net/Gross
weight
Kg
42 / 45
50/53
Refrigerant
type
g
R410A/1370g
R410A/1780g
Design
pressure
MPa
4.2/1.5
4.2/1.5
Refrigerant
piping
Liquid
side/
Gas
side
mm(inch)
6.35/
12.7(1/4"/1/2")
9.52/
16(3/8"/5/8")
Max.
refrigerant
pipe
length
m
25
25
Max.
difference
in
level
m
10
10
Connection
wiring
1.5(Optional)
1.0(Optional)
Plug
type
1.5 / ---
--
Thermostat
type
Remote Control
Remote Control
Operation
temp
℃
17-30
17-30
Ambient
temp
(cooling/heating)
℃
18-43/-7-24
18-43/-7-24
Application
area
m
2
26-44
35-58