MLCAC-UTSM-2010-10
Troubleshooting
Outdoor Units 89
9. P2 malfunction
P2 display
Low pressure protection
Judge 1: The wiring between the low pressure switch and main control
board is connected well or correctly
Judge 2: Whether the low pressure switch is broken
Connect it well
Method: Short connect the low pressure switch socket, check
whether the system can run normally
Check whether the refrigerant system is ok
Yes
No
Judge 3: Check whether the outdoor ambient temperature is too low
Yes
Stop the unit
No
Judge 4: The refrigerant of the system is leakage
Yes
Method: Connect the pressure gauge to the gauge joint of the system,
check whether the pressure is lower than 0.14MPa
Leak hunting: Charge nitrogen or refrigerant to
the system, if the leakage is serious, there will
be distinct gas leakage “cici” sound; if the
leakage is slight, use the suds (mixture of water
and abluent is also ok if it can make bubble) or
electronic leak detector.
Judge 5: The refrigerant pipe is blocked
Yes
Let the refrigerant out, then use the high pressure
nitrogen or refrigerant to blow pipe, vacuumize and
charge the refrigerant again
No
Replace outdoor main board
No
No
Yes
Replace low pressure switch
Содержание MLCAC-UTSM-2010-10
Страница 1: ...MIDEA LCAC 50Hz R410A DC Inverter Service Manual 2011 ...
Страница 2: ......
Страница 4: ......
Страница 16: ...Service Space MLCAC UTSM 2010 10 12 Four way Cassette Type 3 Service Space ...
Страница 17: ...MLCAC UTSM 2010 10 Wiring Diagrams Four way Cassette Type 13 4 Wiring Diagrams MCC 36HRDN1 MCC 48HRDN1 ...
Страница 21: ...MLCAC UTSM 2010 10 The Specification of Power Four way Cassette Type 17 9 The Specification of Power ...
Страница 22: ...Field Wiring MLCAC UTSM 2010 10 18 Four way Cassette Type 10 Field Wiring Wiring chart ...
Страница 23: ...MLCAC UTSM 2010 10 Field Wiring Four way Cassette Type 19 ...
Страница 32: ...The Specification of Power MLCAC UTSM 2010 10 28 Duct Type 9 The Specification of Power ...
Страница 33: ...MLCAC UTSM 2010 10 Field Wiring Duct Type 29 10 Field Wiring ...
Страница 34: ...Field Wiring MLCAC UTSM 2010 10 30 Duct Type Air conditioner link circuit ...
Страница 37: ......
Страница 40: ...Service Space MLCAC UTSM 2010 10 58 Ceiling Floor Type 3 Service Space ...
Страница 41: ...MLCAC UTSM 2010 10 Wiring Diagrams Ceiling Floor Type 59 4 Wiring Diagrams MUB 36HRDN1 MUB 48HRDN1 ...
Страница 46: ...The Specification of Power MLCAC UTSM 2010 10 64 Ceiling Floor Type 9 The Specification of Power ...
Страница 47: ...MLCAC UTSM 2010 10 Field Wiring Ceiling Floor Type 65 10 Field Wiring ...
Страница 48: ...Field Wiring MLCAC UTSM 2010 10 66 Ceiling Floor Type ...
Страница 51: ...MLCAC UTSM 2010 10 Service Space Outdoor Units 69 2 Service Space ...
Страница 53: ...MLCAC UTSM 2010 10 Wiring Diagrams Outdoor Units 71 4 Wiring Diagrams MOUB 36HDN1 Q MOU 48HDN1 MOUB 36HDN1 R ...
Страница 54: ...Wiring Diagrams MLCAC UTSM 2010 10 72 Outdoor Units MOUB 48HDN1 R ...
Страница 60: ...Troubleshooting MLCAC UTSM 2010 10 78 Outdoor Units For Duct type ...
Страница 89: ...MLCAC UTSM 2010 10 Control Control 107 Part 5 Control 1 Controller 108 ...