background image

 6

INSTALLATION   INSTRUCTIONS

1. For the left-hand and right-hand  piping, 
    remove the pipe cover from the side 
    panel.    
2. For the rear-right-hand and rear-left-hand 
    piping, install the piping as shown. 

3. Fix the end of the connective pipe. (Refer 
    to Tightening Connection in 
    REFRIGERANT PIPING CONNECTION)

Connective pipe installation

1. Pass the piping through the hole in the 
    wall.
2. Put the upper claw at  the back of the
    indoor unit on  the upper  hook of  the 
    installation  plate, move  the indoor unit
    from side to side to see that it is securely 
    hooked (see Fig.10 & Fig.11).
3. Piping can easily be made  by lifting the 
    indoor unit with a cushioning material 
    between the indoor unit and the wall. 
    Get it out after finish piping.
4. Push the lower part of the indoor unit up 
    on the wall, then move the indoor unit 
    from side to side, up and down to check
    if it is hooked securely.

4. Indoor unit installation

2. When connecting extension drain hose, 
    insulate the connecting part of extension  
    drain hose with a shield pipe, do not let 
    the drain hose slack.

Right-hand piping

Left-hand piping

Rear-right piping

Rear-left piping

Fig.8

Fig.9

Fig.11

Upper Hook

Lower Hook

Cushioning

material

Fig.10

Fig.7

Do not block water flow by a rise.

Do not put the end of 
drain hose into water.

3. Connective Pipe and Drainage 
     Installation

1. Run the drain hose sloping downward. 
    Do not install the drain hose as 
    illustrated in Fig.7.

Drainage

Содержание INVERTER SPLIT TYPE ROOM AIR CONDITIONER

Страница 1: ...ompletely before installing the product If the power cord is damaged replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the nationa...

Страница 2: ...use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the...

Страница 3: ...ring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it wil...

Страница 4: ...ated by arrows from wall or other obstacles Do not place animals and plants in the path of the air inlet or outlet Take the air conditioner weight into account and select a place where noise vibration...

Страница 5: ...e 60c m abo ve 30cm above Air Filter Air Outlet 30cm above Wrapping tape B 200cm above Additional drain pipe Accessories Parts you must purchase Consult the dealer about the pipe size 6 35 9 53 12 7 9...

Страница 6: ...mensions are in mm unless otherwise stated 1 Determine hole positions according to the diagramdetailed in Fig 5 Drill one 1 hole 65mm slanting slightly to outdoor side 2 Always use wall hole conduit w...

Страница 7: ...the indoor unit with a cushioning material between the indoor unit and the wall Get it out after finish piping 4 Push the lower part of the indoor unit up on the wall then move the indoor unit from s...

Страница 8: ...se sloped downward to drain out the condensed water smoothly CAUTION Install the outdoor unit on a rigid base to prevent increasing noise level and vibration Determine the air outlet direction where t...

Страница 9: ...r tube pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing Pipe Reamer Point down Fig 16 Fig 17 Outdoor unit dimension mm WxHxD A mm B mm 530 290 484 600...

Страница 10: ...air conditioner and explain to the client until the problem is solved 2 Power voltage should be in the range of 90 110 of rated voltage 3 The creepage protector and main power switch with a 1 5 times...

Страница 11: ...oosening the screw as shown in Fig 22 4 Ensure the colour of wires of outdoor unit and the terminal Nos are the same to the indoor s respectively 5 Wrap those cables not connected with terminals with...

Страница 12: ...connecting means must be provided and shall be located within sight from and readily accessible from the air conditioner Connecting cable with conduit shall go through the hole of the conduit panel No...

Страница 13: ...the fixed wiring and have an air gap contact separation of at least 3mm in each active phase conductors CAUTION CAUTION CAUTION CAUTION Air and moisture in the refrigerant system have undesirable eff...

Страница 14: ...ully open the handle Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose theflare nut of the Lo valve on the gas pipe side and check that the air is...

Страница 15: ...If bubbles come out the pipes have leakage 2 Leak detector Use the leak detector to check for leakage Test running Safety and leakage check 14 TEST RUNNING Manual control button AUTO COOL Perform tes...

Страница 16: ...CS120I BP9A1 LH 202000192327 20110613 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Отзывы: