Service Manual_2018-V2.0
34
11
)
Replace the compressorand welding the compressor
pipeline.-
❿
Welding the process pipeline.-
⓫
Welding the
low-pressure muffler.-
⓬
Welding the high-pressure
exhaust pipe.
12
)
Replace thefilter, Cu-Fe tubes welding
⓭
used Ag
welding rod, Cu-Cu tubes welding
⓮
used Cu welding
rod.
13
)
Vacuum system,The degree of vacuum below 6Pa.
14
)
Perfusion refrigerant.
15
)
Use the vise grip pliers clamp the middle of the
process pipe, thenseal welding process tube
⓯⓰
.
Condenser fan motor