11. Compressor
11.1Compressor on and off Control specifications
1.1 When one of the following conditions is met, the compressor stops:
1)
Tr ≤ Trt
;
2) The compressor runs continuously for more than 3 hours (Stop 5 minutes);
1.2 When all the following conditions are met, the compressor starts up:
1)
Tr ≥Trk;
2) Compressor downtime is more than 5min.
★
When 1.1 and 1.2 are not satisfied, the compressor maintains the original state
11.2Variable frequency driver board fault analysis
running status of LED
Fault cause
not Light
not Working
Blink once: light 1S, extinguish1S
Standby
Blink once: light 0.5S, extinguish1.5S
Overcurrent
Blink
twice:
light
0.5S,
extinguish0.5S,
interval
time(extinguish) is 1.5 second
Overvoltage
Blink four times: light 0.5S, extinguish0.5S, interval
time(extinguish) is 1.5 second
Undervoltage
Blink eight times: light 0.5S, extinguish0.5S, interval
time(extinguish) is 1.5 second
LOCK
Blink sixteen times: light 0.5S, extinguish0.5S, interval
time(extinguish) is 1.5 second
Overload protection
Содержание HC-957WEN
Страница 5: ...Service Manual_2018 V2 0 5 1 Significant update notes None...
Страница 24: ...Service Manual_2018 V2 0 24 7 3Circulating route of cooling air...
Страница 52: ...Service Manual_2018 V2 0 52 12 Troubleshooting Method 12 1 No cooling Air cooling Electronic...
Страница 53: ...Service Manual_2018 V2 0 53 12 2 No working of compressor 12 3 Inside frosting no defrosting...
Страница 54: ...Service Manual_2018 V2 0 54 12 4 Inside frosting no defrosting Maintenance guidelines...
Страница 55: ...Service Manual_2018 V2 0 55 12 5 Light is not on 12 6Fan failure...
Страница 56: ...Service Manual_2018 V2 0 56 12 7Defective defrost circuit 12 8Noise...
Страница 58: ...Service Manual_2018 V2 0 58 13 Figures and details of repair parts See this section in the TSP...