5
Installation & Owner‘s Manual
4.3.1 Electric Wiring Illustration
CAUTION
4.3 Electric Connection
Fig.4-2
50mm larger than
the dia. of unit
Max.
22mm
Heat Pump
Water Heater
WARNING
4.4 Installation checklist
4.4.1 Location
1) The flooring beneath the water heater must be able to support
the weight of the water heater when filled with water (286kg full).
2) Located indoors (such as a basement or garage) and in a
vertical position. Sheltered from freezing temperatures.
4.2 Installation verticality requirement
To smoothly drain condensate from unit, please install the main unit is
on a horizontal floor. Otherwise, please ensuring the drain vent is at
the lowest place. Recommended inclination angle of unit to the
ground
should be no more than 2°.
●
Set the electric leakage protector according to the relevant
electric technical standards of the State.
●
The power cord and signal cord shall be laid out neatly and
properly without mutual interference or contacting the connec-
tion pipe or valve.
● After wire connection, check it again and make sure of connec
-
tion before power is turned on.
Fig.4-3
Drain
≤2
o
Drain
The unit must be installed with an RCD near the power supply
and must be effectively earthed.
Fig.4-4
T3:
Evaporator Temp. Sensor
T4: Ambient Temp. Sensor
T5L: Tank Temp. Sensor
TP: Discharge Temp. Sensor
Earthing
TH: Suction Temp. Sensor
Ambient temperature sensor
Suction temperature sensor
CN20
SW3
SW3-2
SW2
SW2-1
Without
2150W
1070W
3200W
1600W
Fan capacitor