Installation & Owner‘s Manual

Table 3-1

Accessory Name

Qty. Sharp

Purpose

1

Owner’s & Installation

Manual

Installation and use instruction

This manual

1

Drain pipe for 

water condensation

Use for draining the condensate 

water (Has been connected to 

the lower condensate drain port)

  If the supply cord is damaged,  it must be replaced by the 

manufacturer or its service agent or a similarly qualified person.

  DISPOSAL:  Do not dispose this product as 

unsorted municipal waste. Collection of such 

waste separately for special treatment is neces-

sary. Do not dispose of electrical appliances as 

unsorted municipal waste, use separate collec-

tion facilities. Contact your local government for 

information regarding the collection systems 

available.

  If electrical appliances are disposed of in landfills or dumps, 

hazardous substances can leak into the groundwater and get 

into the food chain, damaging your health and well-being.

3.  BEFORE INSTALLATION

3.1  Unpacking

3.1.1  Accessories

3.1.2  How to transport

1)  In order to avoid scratching or deforming 

the unit surface, apply guard boards 

to the contacting surfaces.

No contact of fingers and other things 

with the vanes.

Don’t incline the unit more than 75° 

in moving, and keep it vertical when

installing.

2)  This unit is heavy, it needs to be carried by two or more persons, 

othewise might cause injury and damage.

3.2  Location requirements

1) 

Enough  space  for  installation  and  maintenance  should  be 

preserved.    

2) The air inlet and outlet should be free from obstacles and strong 

wind.

3) The base surface should be flat, surface should be inclined no 

more than 2° and able to bear the weight of the unit and suitable 

for installing the unit without increasing noise or vibration.

4) The operating noise and air flow expelled should not affect 

neighbors.    

5)  No flammable gas nearby.

6)  It should be convenient for piping and wiring.

7) If it is installed in indoor space, it might cause indoor temperature 

to

 

decrease and noise, Please take preventive measures for this.

8) If the unit has to be installed on a metal part of building, make 

sure the electric insulation meets the relevant local electric 

standard. 

>75°

Gradient limit>75°

CAUTION

●  The earthing pole of socket must be well grounded, make sure 

that power supply socket and plug are dry and connected tightly.

● 

 Before cleaning, be sure to stop the operation and turn the 

breaker off or pull out the power plug. Otherwise, an electric 

shock and injury may be caused.

●   

Water temperature over 50

 can 

cause severe burns instantly or 

death from scalds.  Children, 

disabled and elderly are at 

highest risk of being scalded. 

Feel water before bathing or 

showering.  Water  temperature 

limiting valves are required as 

per AS 3500.

●   Do not operate the unit with a wet hand. An electric shock may 

be caused.

●  The installation height of power supply should be over 1.8m, if 

there is any water exposure, steps must be taken to separate 

the power supply from water.

●   A one-way valve must be installed on the water inlet side, as 

well as an isolation value.

●  It is normal for some water to be released from the PTR valve 

during operation. But, if there is a large volume of water, call 

your service agent for instructions. After long term use, check 

the unit base and fittings. If damaged, the unit may sink, resulting 

in  injury. Arrange  the  drain  pipe  to  ensure  smooth  draining. 

Improper drainage work may cause wetting of the building, 

furniture etc. Do not touch the inner parts of the controller or 

remove the front panel. Some parts inside are dangerous to 

touch, and damage may be caused.

●  

Do not turn off the power supply.

System will stop or restart heating automatically. A continuous 

power supply for water heating is necessary, except service 

and maintenance. 

Hydrogen gas is extremely flammable, and may build up if no 

water is drawn of for several weeks. To reduce the risk of 

injury under these conditions, it is recommended that the hot 

water tap is opened for several minutes at the kitchen sink 

before using any electrical appliance connected to the hot 

water system. When hydrogen is present, there will probably 

be an unusual sound such as air escaping through the pipe as 

the water begins to flow. There should be no smoking or open 

flame near the tap at the time it is open. 

Содержание 190RDN3-E

Страница 1: ...ATION OWNER S MANUAL Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference ALL IN ONE Type Air source Heat Pump Water...

Страница 2: ...loding Continuous leakage of water from the valve may indicate a problem with the water heater THE INSTALLATION MUST COMPLY WITH THE REQUIREMENTS OF AS NZS 3500 4 AS NZS 3000 and all local codes and r...

Страница 3: ...anual When ordering repair parts please always give the following information 1 Model serial and product number 2 Part name on location Fan Assy PTR Valve Top Cover Evaporator Filter Magnesian Stick R...

Страница 4: ...should be supervised to ensure that they do not play with the appliance NOTE Above calculations are based on ideal conditions the final amount will be different the actual running will vary with condi...

Страница 5: ...be installed on a metal part of building make sure the electric insulation meets the relevant local electric standard 75 Gradient limit 75 CAUTION The earthing pole of socket must be well grounded ma...

Страница 6: ...equire the water piping conden sate piping and drain piping to be insulated to shelter agianst freezing CAUTION CAUTION WARNING The unit must be securely fixed otherwise noise and vibartion may result...

Страница 7: ...heat resistant and durable 2 Installation of the pipe for PTR valve The valve connecting thread is RC3 4 internal thread After installation it must be confirmed that the drainpipe outlet is exposed i...

Страница 8: ...drain vent is at the lowest place Recommended inclination angle of unit to the ground should be no more than 2 Set the electric leakage protector according to the relevant electric technical standard...

Страница 9: ...re found in aerosol sprays detergents bleaches cleaning solvents air fresheners paint and varnish removers refrigerants and many other commercial and household products In addition excessive dust and...

Страница 10: ...e system will defrost automatically to keep effective performance about 5 15min At defrosting time the compressor will stop but fan motor will still run Heat up Time There are different heat up times...

Страница 11: ...tlet water is unclean Turn the tap on and the water will be flushed clean 5 2 3 Basic function 1 Weekly disinfect function Under disinfection mode unit immediately starts to heat water up to 65 to kil...

Страница 12: ...heater Mode is selected at the off time ALARM When unit is displaying protection error will flash with 5Hz frequency as well as buzzer sounding 3 times every minute until protection error eliminated o...

Страница 13: ...e will be extinguished CLOCK will be displayed all the time shows current clock on normal time shows setting clock when setting timer TIME CONFLICT Reserved function will be displayed if the timer whi...

Страница 14: ...or more than 3 seconds and the Timer TIME ON TIME OFF function will be canceled INCREASE UP If button is unlocked corresponding value will increase by pushing When setting temperature press for more t...

Страница 15: ...3 1 2 3 6 4 Auto restart If power is disconnected the unit can remember some of the setting parameters On or Off state operating mode setting water tempera ture when it re powers on the unit will be o...

Страница 16: ...son to service the unit If PCB current_induction_circuit check the current difference between L N 14mA system consider it as electric leakage error Electric leakage error Compressor suction temperatur...

Страница 17: ...draining exit The min heat resistance of the drain pipe is not less than 93 if the drain pipe can not meet the requirement please open the cold water inlet valve open the hot water tap until there is...

Страница 18: ...e 40W Air out from sideward 440W 2150W 1 0MPa DN20 DN20 DN20 DN20 Default 63 38 70 adjustable T20A 250VAC 568 1580mm 190L 90kg 2780W 12 1A 1500W 2150W Water pipeline system RSJ 15 190RDN3 E Table 9 1...

Страница 19: ...ult or defect in the installation of the heat pump 3 If corrosion has occurred because the anode has not been changed in accordance with the owner s manual 4 If a cold water expansion valve check valv...

Страница 20: ...MDV11IU 055BW DZ 2020001A9998...

Отзывы: