INSTALLATION AND OPERATION MANUAL, GAS KETTLE, MODEL GL-30
10156R2
21
2012-11-28
6.0 SERVICE
WARNING: Disconnect unit from power supply before cleaning or
servicing appliance.
GENERAL
When any difficulty arises always check that the unit has been connected to the gas supply
type and voltage for which it was supplied. This can be done by examining the serial plate on
the lower right side of the unit. It will list the gas type and voltage for which the unit was
manufactured.
Wiring diagrams for the unit are located in a small envelope affixed to the rear side of the front
control panel.
Orifice Size
Unit
Total Input
Natural
Propane
GL-30
100,000 BTU/Hour
29
44
MANIFOLD PRESSURE
Natural Gas - 4 inches W.C.
LP Gas - 10 inches W.C.
PILOT ORIFICE SIZES:
MODEL
NATURAL
PROPANE
GL-30
.026 IN.
.014 IN.
PILOT:
Pilot adjustment is part of the combination control valve located in the low front access door. It
is located just to the left of the pilot tube on the inlet (top) side of the gas valve. Remove the
large screw on the top left side of the pilot tube outlet. Below the screw is a slotted adjustment
screw.