![Middleby CROWN GL-30 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/middleby/crown-gl-30/crown-gl-30_installation-and-operation-manual_1790436010.webp)
INSTALLATION AND OPERATION MANUAL, GAS KETTLE, MODEL GL-30
10156R2
10
2012-11-28
Figure 1
4.0 OPERATION
WARNING: In the event of main burner ignition failure, a 5 minute
purge period must be observed prior to re-establishing ignition
source.
WARNING: In the event you smell gas, shut down equipment at the
main shut off valve and contact the local gas company or gas
supplier for service.
CAUTION: If you smell gas during the lighting procedure,
immediately shut off the gas supply until the leak has been
corrected.
GAS CONTROL INSTRUCTIONS:
START UP
1.
Turn thermostat to “OFF” position and power
switch to “OFF” position.
2.
Open control panel access door located on
right side at bottom.
3.
Turn dial on combination control to “PILOT”
position by rotating knob counterclockwise.
NOTE: Any gas service valves exterior to the
unit should be open.
4.
Lift the shutter (see Fig. 1) on the heat shield
to gain access to the pilot burner, which is
located on the right side of the left burner,
approximately 6 inches into the combustion
chamber.
Contact the factory, the factory representative or a local service company to