32
3.2.3
Air Flow Meter
Air flow meters generally have vane type, hot wire type, digital type, etc.; among them: vane type and hot wire type
are both analog output, and the output voltage is proportional to the air flow, generally 0.5V~4.5V, but the non-
linear ratio, It needs to be corrected in the ECM; the general output voltage is about 1V at idling speed, and the
voltage rises rapidly during acceleration, reaching a voltage of 4V~4.5V. After stopping the acceleration, it will
return to the idling voltage; the output shows 0V or 5V is not normal.
The digital type has a digital circuit inside the sensor. The output signal is a square wave. The frequency is used to
represent the air flow. A higher frequency means a higher air intake. Use a BNC to banana cable and connect one
end to channel 1 of the oscilloscope. The black plug on the other end is grounded, and the red connector is connected
to the signal wire of the air flow sensor with a needle. Start the vehicle, quickly depress the accelerator pedal and
release it to test, you can view the waveform.
Use the ATO oscilloscope to test the throttle air flowmeter sensor (the air flowmeter is divided into three types:
analog, digital, and hot wire, please test according to different types), the specific operation is shown in Figure 3-
12:
Figure 3-12 Air flow meter
Содержание ATO1000 Series
Страница 1: ......
Страница 2: ...Version Info Version Date Remarks V1 0 2020 06 ...
Страница 52: ...Chapter 3 Automotive Test 49 Figure 3 30 Electronic fuel pump test ...
Страница 67: ...64 Figure 3 45 CAN BUS Test The figure below is the actual measurement of the CAN bus of a certain model ...
Страница 71: ...68 Figure 3 49 K line test ...
Страница 79: ...76 Figure 3 57 Mazda 6 Cylinder internal pressure measurement ...
Страница 169: ...166 Figure 12 15 Locking Interface ...