62
MDS iNET 900 Series User’s Guide
MDS 05-2806A01, Rev. E.1
•
Custom Data Buffer Size
(Custom Packet Mode only)—Maxi-
mum amount of characters, that the Remote end will buffer
locally before starting to transmit data through the serial port.
[
16, 32, 64, 128, 256; 32
]
•
Commit Changes and Exit Wizard
—Save and execute changes
made on this screen (Shown only after changes have been
entered.)
Invisible place holder
Figure 3-27. UDP Point-to-Point Menu
Use UDP point-to-point configuration to send information to a single
device.
•
Status
—Enable/Disable the serial data port.
•
IP Protocol
—UDP Point-to-Point. This is the type of IP port
that will be offered by the transceiver’s serial device server.
[
TCP, UDP, PPP; TCP
]
•
Remote IP Address
—Data received through the serial port is
sent to this IP address. To reach multiple Remotes in the net-
work, use UDP Point-to-Multipoint.
[
Any legal IP address; 0.0.0.0
]
•
Remote IP Port
—The destination IP port for data packets
received through the serial port on the transceiver. [
1–64,000;
COM1: 30010, COM2: 30011
]
•
Local IP Port
—Port number where data is received and passed
through to the serial port. This port number must be used by
the application connecting to this transceiver. [
1–64,000;
COM1: 30010, COM2: 30011
]
Содержание iNET 900 Series
Страница 10: ...2 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Страница 26: ...18 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Страница 118: ...110 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Страница 120: ...112 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Страница 136: ...128 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Страница 148: ...140 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Страница 150: ...142 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Страница 164: ...156 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Страница 172: ...164 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...