DX-2200
– Dual-view 2x1 SDI Video Switcher
Page 48 of 87
Figure 18: Example 1 - red text OSD with white background
This text field can be updated and replaced with new text have the same attributes
by overwriting with a new text string. For example, if the new text was:
This is an updated text string for Text Field 1
The command would be:
S1T
“This is an updated text string for Text Field 1”
SU
Example 2:
The addition of a second text field with the default font and color:
Text: A text sample using default values for Text Field 2
Default text size at 720p: 002
Position: X=0600, Y=0200
Default color: white
The SERIAL Commands to display this text as Field 2 are as follows:
S2T
“A text sample using default size for Text Field 2
S2X0600
S2Y0200
S2S