DX-2200
– Dual-view 2x1 SDI Video Switcher
Page 46 of 87
Command
Code
Mode of Operation
SnnKcs
Set the control parameters for Graphic Field nn.
c = Parameter identifier, referenced by letter, from A to H inclusive
s = 1 to enable the function, or 0 to disable
For Corner Marker Fields,
parameter A = suppress top-left marker
parameter B = suppress bottom-left marker
parameter C = suppress top-right marker
parameter D = suppress bottom-right marker
SnnImmmm
Set the image number for Graphic Field nn to the value mmmm.
SnnT"ASCII text"
Set the ASCII text string for Graphic Field nn. The text string is used when the
Field type is set to Text.
"ASCII text" is the content of the string framed with quotation marks.
SnnFfff
Set the font / size for Field nn. fff is a number of between 1 and 3 digits in
length. The following font/size combinations are available.
1
– Tahoma Bold 26 pixel height
2
– Tahoma Bold 40 pixel height
3
– Tahoma Bold 78 pixel height
4
– Tahoma Bold 156 pixel height
5
– BGP Courier 26 pixel height
6
– BGP Courier 40 pixel height
7
– Larable Bold 26 pixel height
8
– Larable Bold 40 pixel height
9
– Wingdings 40 pixel height
10
– Wingdings 80 pixel height
11
– Wingdings 160 pixel height
The default for 720p and 1080p is font 1 and 2 respectively.
SnnPAxxxx,yyyy
SnnPBxxxx,yyyy
Set location coordinates for Graphic Field nn.
Each Field has two location coordinates referenced by letter, either ‘A’ or ‘B’.
Coordinate A is the top-left position of a Rectangle Field, Text Field, or Corner
Marker Field, and is the center position of a Target Marker Field.
Coordinate B is the bottom-right position of a Rectangle Field or Corner
Marker Field.
xxxx and yyyy are numbers between 1 a 4 digits in length.
SnnXxxxx
Set the x-direction position for coordinate A of the Graphic Field nn. This
command is included for compatibility with the Text Overlay command set.
SnnXaaaa,bbbb
For Graphic Field nn, set the x-direction position for coordinate A to the value
aaaa and set the x-direction coordinate B to the value bbbb.
SnnYyyyy
Set the y-direction position for coordinate A of the Graphic Field nn. This
command is included for compatibility with the Text Overlay command set.
SnnYaaaa,bbbb
For Graphic Field, set the x-direction position for coordinate A to the value
aaaa and set the x-direction coordinate B to the value bbbb.
SnnPAXxxxx
SnnPBXxxxx
For Graphic Field nn, set only the x-direction location of either coordinate A or
coordinate B.
SnnPAYyyyy
SnnPBYyyyy
For Graphic Field nn, set only the y-direction location of either coordinate A or
coordinate B.