Para-

meters

Description 

Value 

О

Timer output type

0

 – without restarting the other timer

- restart the other timer after the end of

 tHi

.

Start   mode,   behavior   after
POWER ON

Without   automatic   completion
of the job after power supply

Automatically   complete   the   job
after power is applied

Start by front.

1            (9*)

5        (13*)

Start  by  front. Restart if after
the end of the cycle the Start
input is active.

2           (10*)

6        (14*)

Start  by  front,   restart   with
each subsequent pulse

3          (11*)

7        (15*)

Start by level. Reboots if the
Start input is active after the
end   of   the   cycle.   In  case   of
Reset failure and active input
Start - also starts.

18          (26*)

Finishes if Start input is active

22          (30*)

Finishes even if the Start input is

not active

(*)   Allowed start from the keyboard.

 The option is common to both timers. To activate, both timers

must be configured with the values in parentheses. Otherwise - forbidden to start from the keyboard.

Р

Timer operation mode

-   999 . 10 

–2

 seconds

1

 -   999 . 10 

–1

 seconds

2

 -   999 seconds

3

 -   999 minutes

 

The choice of 

 from the menu 

A

B

c

 activates menu for

output configuration

Each configuration becomes valid immediately after the transition to the next period,

but the recording  in non-volatile memory is performed when exiting  the main menu for
setting parameters.

7

  t  1  L

outputs

 

Inactive output

Active output

1    2    3    4    5    6

period 

 

moves  the  marker  to 
the right

switches
active / inactive
exit

lists the periods
t1Lo => t1Hi=>t2Lo=>t2Hi
=> return to a higher level

Содержание MS8326

Страница 1: ...TWO CHANNEL TIMER MS8326 v3 11 USER MANUAL PLOVDIV 2010 Document revision 2010 11 12...

Страница 2: ...ly Indication and keypad Display 2 x 3 digits LED 10 mm Display range 0 999 Resolution Up to 0 01s Keypad XXX min s s 10 1 s 10 2 Display membrane Power supply Power supply voltage 230V max 20mA 50 Hz...

Страница 3: ...rs can work in the modes 999 min 999 s 999 s 10 1 999 s 10 2 Each timer counts two times time tLo and time tHi and for each of them the user sets a group of outputs to be active When an output is conn...

Страница 4: ...e loaded A separate RESET is possible via the corresponding external inputs 2 When an active level is applied to one of the Start inputs the corresponding timer loads time tLo and is activated After s...

Страница 5: ...tHi The button combinations shown in the table are used to change the SP SP of timers tLo the buttons are pressed with priority on the left tHi tHi 0 the buttons are pressed with priority on the right...

Страница 6: ...elow the symbol exits the setting mode By button below the symbol enters the menu for configuring the outputs When one of the two timers is selected the following symbols appear on the display O P c B...

Страница 7: ...if Start input is active 22 30 Finishes even if the Start input is not active Allowed start from the keyboard The option is common to both timers To activate both timers must be configured with the v...

Страница 8: ...rounded at only one end Wires that carry a similar type of signals can be packed together but if the signals are different the wires must be separated to prevent electromagnetic interaction When there...

Страница 9: ...a bad transport bad conservation wrong exploitation naturedisasters not following the instructions and the cases when there is an attempt to fix anydefects by other people In those cases the issue is...

Отзывы: