Para-
meters
Description
Value
О
Timer output type
0
– without restarting the other timer
1
- restart the other timer after the end of
tHi
.
Start mode, behavior after
POWER ON
Without automatic completion
of the job after power supply
Automatically complete the job
after power is applied
Start by front.
1 (9*)
5 (13*)
Start by front. Restart if after
the end of the cycle the Start
input is active.
2 (10*)
6 (14*)
Start by front, restart with
each subsequent pulse
3 (11*)
7 (15*)
Start by level. Reboots if the
Start input is active after the
end of the cycle. In case of
Reset failure and active input
Start - also starts.
18 (26*)
Finishes if Start input is active
22 (30*)
Finishes even if the Start input is
not active
(*) Allowed start from the keyboard.
The option is common to both timers. To activate, both timers
must be configured with the values in parentheses. Otherwise - forbidden to start from the keyboard.
Р
Timer operation mode
0
- 999 . 10
–2
seconds
1
- 999 . 10
–1
seconds
2
- 999 seconds
3
- 999 minutes
The choice of
from the menu
A
B
c
activates menu for
output configuration
Each configuration becomes valid immediately after the transition to the next period,
but the recording in non-volatile memory is performed when exiting the main menu for
setting parameters.
7
t 1 L
outputs
Inactive output
Active output
1 2 3 4 5 6
period
moves the marker to
the right
switches
active / inactive
exit
lists the periods
t1Lo => t1Hi=>t2Lo=>t2Hi
=> return to a higher level