background image

RESET ON BOTH TIMERS FROM THE KEYBOARD

RESET 

can be applied to both timers by pressing buttons simultaneously:

On display:  

[- - -]  [- - -]

V. EDIT OF SETTINGS 

In this mode, the timer operation mode, start mode and internal restart permission are set.
Entering   this   mode   is   done   by   pressing   and   holding   for   more   than   5   seconds

simultaneously on the buttons

The following symbols appear on the display:

A

B

c

By button below the symbol 'A'  enters the setting of  Timer 1 parameters .
By button below the symbol 'В'  enters the setting of  Timer 2parameters .
By button below the symbol   'с'   exits the setting mode.
By button below the symbol '

' enters the menu for configuring the outputs.

When one of the two timers is selected, the following symbols appear on the display:

O

P

c

By button below the symbol  

О

 the output type of the respective timer is set.

By button below the symbol    the start mode for the respective timer is set.
By button below the symbol 

Р

 the reporting format of the respective timer is set.

By button below the symbol 

с

 exits to the above mode.

When editing the corresponding values, the display shows the following:

o

c

X

X

X

where XXX is the value to be edited with the buttons below the left display.
By button below the symbol 

о

 the entered value is confirmed and exits to a higher level

of the menu.

6

Содержание MS8326

Страница 1: ...TWO CHANNEL TIMER MS8326 v3 11 USER MANUAL PLOVDIV 2010 Document revision 2010 11 12...

Страница 2: ...ly Indication and keypad Display 2 x 3 digits LED 10 mm Display range 0 999 Resolution Up to 0 01s Keypad XXX min s s 10 1 s 10 2 Display membrane Power supply Power supply voltage 230V max 20mA 50 Hz...

Страница 3: ...rs can work in the modes 999 min 999 s 999 s 10 1 999 s 10 2 Each timer counts two times time tLo and time tHi and for each of them the user sets a group of outputs to be active When an output is conn...

Страница 4: ...e loaded A separate RESET is possible via the corresponding external inputs 2 When an active level is applied to one of the Start inputs the corresponding timer loads time tLo and is activated After s...

Страница 5: ...tHi The button combinations shown in the table are used to change the SP SP of timers tLo the buttons are pressed with priority on the left tHi tHi 0 the buttons are pressed with priority on the right...

Страница 6: ...elow the symbol exits the setting mode By button below the symbol enters the menu for configuring the outputs When one of the two timers is selected the following symbols appear on the display O P c B...

Страница 7: ...if Start input is active 22 30 Finishes even if the Start input is not active Allowed start from the keyboard The option is common to both timers To activate both timers must be configured with the v...

Страница 8: ...rounded at only one end Wires that carry a similar type of signals can be packed together but if the signals are different the wires must be separated to prevent electromagnetic interaction When there...

Страница 9: ...a bad transport bad conservation wrong exploitation naturedisasters not following the instructions and the cases when there is an attempt to fix anydefects by other people In those cases the issue is...

Отзывы: