INSTALLATION INSTRUCTIONS
W A R N I N G – I S O L A T E M A I N S B E F O R E
I N S T A L L A T I O N & S E R V I C I N G
THE INSTALLATION SHOULD BE CARRIED OUT BY
A SUITABLY QUALIFIED PERSON, IN
ACCORDANCE WITH THE CURRENT EDITION OF
THE I.E.E. WIRING REGULATIONS.
WARNING :
All Powersaver products must be
earthed, using the earth terminals at the rear of
the switch. The following cabling is recommend
L & N - 1.5mm² - 4.0mm² fixed
- 1.5mm² - 2.5mm² flexible (retro fit
applications (only in conjunction with 143609
surface box)
L Out & N Out - 1.5mm² - 2.5mm² fixed or
flexible
Provision must be made in the fixed wiring for a
means of disconnection from the supply having a
contact separation of at least 3mm on all poles.
This can be provided by the consumer unit.
The Powersaver Product Range are independently
mounted time switches, of electronic construction,
which can be surface or flush mounted. For flush
fitting, a metal box of at least 32mm internal depth
should be fitted with the earth terminal at the
bottom.
For surface mounting, use a patress box with a
minimum internal depth of 32mm.
Do not remove the Powersaver from its packaging
until the patress/wall box is fitted and cleared of
dust & debris. The Powersaver Range is suitable
for use in a normal pollution situation.
The cable clamp at the rear of the unit is for
outgoing cables to the appliance only.
CONNECTION WARNING:
Isolate mains before installing. Supply
terminals are for fixed wiring only. Load terminals
are for fixed or flexible wiring. Remove 8mm of
insulation from each wire and twist any multiple
connection together.
All earth conductors must be sleeved
(green/yellow) and connected to earth terminal
using earth terminals provided on rear of switch.
Fit the Powersaver to the patress box using screws
provided.
When cutting the aperture for the output flexible
cord, ensure no sharp edges remain.
PLEASE NOTE : This product is not
suitable for mounting on unearthed metal or met-
alised surfaces.
Wiring Diagram
CONTACT RATING
16A Resistive, 240V a.c.
SUPPLY
240V, 50-60Hz a.c.
FIXING
Single Patress – Surface & Flush
Mounting
RESOLUTION OF PROGRAMS
10 Minutes
POWER CONSUMPTION
10.3VA Maximum
LIVE PARTS PROTECTION
This unit is totally protected by the
enclosure
DIRT & MOISTURE PROTECTION
IP40
SHOCK PROTECTION
Class 1(This must be connected to
earth)
CASE MATERIAL
Polycarbonate, PT1 175
TEMPERATURE RATING
T35
OPERATING TEMPERATURE
0ºC to +35ºC
MEMORY RESERVE
(except Boost)
4 Hours – when on power for previous
12 hours
DISPLAY
Liquid Crystal Display
(Boost product has no display)
PROGRAM SETTIGNS
24/7 - Max 3 On & 3 Off operations
(7 days) each day independantly
programmable.
Weekly - Max 3 On & 3 Off operations
(Mon-Fri), Max 3 On & 3 Off alternative
operations (Sat/Sun).
Daily - Max 3 On & 3 Off operations
(Daily).
BOOST FACILITY
User selectable – ½, 1 or 2 hours
TYPE OF ACTION
Type 1B
CONTROL POLLUTION CATEGORY
Normal
Specification
SERVICE AND WARRANTY
Your Powersaver controller is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 2 years from the Date of Manufacture. If it should
become defective, please contact your installer or supplier for a replacement unit.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the Company operates a Customer Care
Policy. This means that we welcome your comments and complaints, as it can help us to improve our
services to you, our customer.
Due to our policy of continuous product improvement and development, the specifications in this
guide may be subject to change without prior notice.
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel: 01475 745131 Fax: 01475 744567
Email: [email protected]
Web: www.sangamo.co.uk
Flush
Mounting
Surface
Mounting
2 HOURS / 5 HOURS
1 HOUR / 3 HOURS
1/2 HOUR / 1 HOUR
BOOST / BOOST MAXI
DAILY
WEEKLY & 24/7
( PSB )
( PSB MAXI )
( PSD )
( PSW )
( PS24/7 )
L
N Out
N
L Out
EARTH
LIVE
NEUTRAL
LOAD
MAINS IN