migra MPB CAN
Large Format Graphics Compatible LED Display with CANopen Interface
Page 64
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
25-Pin Sub-Miniature Plug Connector
(with optional parallel input only)
Binary data:
Data with a value within a range of 0 to 255 as a text
number, graphic number, macro number or as an ASCII
character of a variable to be displayed.
Display / clear:
Displays or clears the selected object from the screen.
Display text:
Displays or clears the selected text from the screen.
Display graphic:
Displays or clears the selected graphic from the screen.
Display variable:
Displays the ASCII character configured by means of
binary data at the position of the selected variable.
Execute macro:
Starts / stops macro execution at the selected macro.
Strobe:
Configured data are activated by applying a high level
signal to pin 16 (> 110 ms). The command is executed
no later than 100 ms after the rising edge, unless the
display is still busy processing another command.
Details regarding the parallel inputs are included in chapter “Parallel Interface”.
Pin 1
Binary data 2
0
Pin 2
Binary data 2
1
Pin 3
Binary data 2
2
Pin 4
Binary data 2
3
Pin 5
Binary data 2
4
Pin 6
Binary data 2
5
Pin 7
Binary data 2
6
Pin 8
Binary data 2
7
Pin 9
Variable no. 2
0
Pin 10
Variable no. 2
1
Pin 11
Variable no. 2
2
Pin 12
Variable no. 2
3
Pin 13
Display / clear (1: on, 0: off)
Variable no. 2
4
Pin 14
Function selection 2
0
Pin 15
Function selection 2
1
Pin 16
Strobe (1: apply value now)
Pins 17 - 24 n.c.
Pin 25
GND