3.11 Parallel Interface
Functions can be initialised via the 16 digital inputs analogous to the
online frames of the serial interface.
3.11.1 Timing at the Parallels Inputs
Data Bits
Strobe
Valid Data
10%
90%
24V
24V
0V
0V
Valid Data
>110ms
>110ms
>110ms
3.11.2 Input Level at the Parallel Inputs
Level
Voltage Range
U (low)
+ 0 to 1.6 V DC
U (high)