migra MPB CAN
Large Format Graphics Compatible LED Display with CANopen Interface
Page 59
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
DIP Switches
DIP switch settings are specified below (0 = OFF and 1 = ON).
DIP switch settings are read in once only during power-up (after
switching the device on).
CAN Node ID:
CAN DIP Switches
CAN Node ID
DIP
7
6
5
4
3
2
1
0
0
0
0
0
0
1
1
d
0
0
0
0
0
1
0
2
d
0
0
0
0
0
1
1
3
d
:
:
1
1
1
1
1
1
1
127
d
Note: Only addresses 1 through 127 are permissible!
CAN Bit Rate:
CAN DIP Switches
CAN Bit Rate
DIP
10
9
8
0
0
0
1000 kBit/s
0
0
1
800 kBit/s
0
1
0
500 kBit/s
0
1
1
250 kBit/s
1
0
0
125 kBit/s
1
0
1
50 kBit/s
1
1
0
20 kBit/s
1
1
1
10 kBit/s
CAN Bus Termination:
CAN Termination DIP Switches CAN Bus Termination
DIP
1
2
0
0
not terminated
1
1
terminated