3.6
Management Port
An additional 10/100/1000Base-T RJ-45 port is intended for IP-based management access.
Per default, the port works like the other RJ-45 ports but the user can configure all needed
options by defining a new IP interface and configuring VLANs. Especially it is possible to
isolate the port from other data traffic.
3.7
Console Port
The device contains a serial RS-232 interface, the console port, as local management
interface. For the console port, a standard RJ-45 connector is used. Nevertheless, the pinning
is different. Use the attached RS-232 cable (Sub-D9 to RJ-45) to connect the console port
with the COM port of a PC. Per default, the following parameters are set:
-
Speed: 115200 bps
-
Data bits: 8
-
Stop bits: 1
-
Flow control: none
-
Parity bit: none
This interface can be used if the IP settings are unknown. Only login (default: admin) and
password (default: microsens) must be known.
3.8
Reset Button
By pressing the reset button for a certain period of time, users can perform the following
tasks:
Reset: To reboot and get the switch back to the previous configuration settings saved.
Factory Default Reset: To restore the original factory default settings back to the switch.
Note: According to the table below, users can easily judge which task is being performed by
reading the LED behaviors while pressing the reset button. Once the LED behaviors are
correctly displayed, users may just release the button.
Task to be
Performed
Time Period of
Pressing Button
SYS LED
Port Status LED
Behavior
Behavior
Reset the switch
2 ~ 7 seconds
blinking
All LEDs are
switched off
green
Restore to defaults
7 ~ 12 seconds
blinking
All LEDs stay on
green
Table 3: Reset and Factory Default Reset