Microsens MS400863M Скачать руководство пользователя страница 14

MS400863M – User Manual

 

 

Page 

14

 of 

15

                            

 

©2019_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com 

 

6

 

Specification

 

 

Switch Characteristic 
 

Type 

Gigabit Ethernet Switch with 4x 10G Uplinks 
Layer 2+, IEEE 802.3 compliant 

Mode of Operation  

Store-and-forward 

Buffer Architecture 

1392 kB on-chip frame buffer 

Aggregate Bandwidth 

128 Gbps 

Switching Database 

32K MAC addresses 

Throughput 

 

130.9 mpps 

Jumbo Frames 

 

10K 

Flow Control 

 

Full Duplex: IEEE 802.3x  
Half Duplex: Back pressure 

Twisted-pair Interface 

 

Number 

 

 

4 (part of combo ports) + 1 (management port) 

Type   

 

 

10/100/1000Base-T   

 

Connector   

 

RJ-45, shielded 

Pin-out 

 

 

Auto-crossing 

 
SFP Interface 

 

Number 

 

 

24 (4 combo ports, shared with RJ-45 ports) 

Type   

 

 

100/1000Base-X SFP slots 

 
SFP+ Interface 

 

Number 

 

 

Type   

 

 

1G/10G SFP+ slots 

 
Power Supply 

 

DC Power Input 

 

-24 ~ -48 VDC 

AC Power Input 

 

100 ~ 240 VAC, 50~60 Hz 

Power Consumption 

max. 38 W 

 

Environmental Conditions 
 

Operating Temperature  -20…+60° C   
Humidity 

 

 

10…90 % (non-condensing) 

 
Mechanic 

 

Size   

 

 

44(H) x 442(W) x 211.2(D) mm 

Weight 

 

 

3.1 kg 

 
 
 
 
 
 
 
 

 

Содержание MS400863M

Страница 1: ...Gigabit Ethernet Switch With 10G Uplinks User Manual MS400863M July 2019...

Страница 2: ...RJ 45 Ports 5 3 4 SFP SFP Ports 5 3 5 LEDs 5 3 6 Management Port 7 3 7 Console Port 7 3 8 Reset Button 7 4 Installing the Switch 8 4 1 Mounting 8 4 1 1 Rack Mounting 8 4 1 2 Desktop or Shelf Mounting...

Страница 3: ...ology the entire packet must be received into a buffer and checked for validity before being forwarded This prevents errors from being propagated throughout the network Additionally the device support...

Страница 4: ...gure 1 only the earth screw is placed at the rear side 3 1 Redundant Power Interface There are dual power inputs on the front panel of the switch for power redundancy requirement the switch has 100 24...

Страница 5: ...re that the configuration of the port speed matches with the used SFP or SFP module 3 5 LEDs The switch includes a display panel for system and port indications that simplify installation and network...

Страница 6: ...1000 Mbps Green Blinking The port is transmitting receiving packets and the connection speed is 1000 Mbps Amber On The port is enabled and established a link to connected device and the connection sp...

Страница 7: ...Speed 115200 bps Data bits 8 Stop bits 1 Flow control none Parity bit none This interface can be used if the IP settings are unknown Only login default admin and password default microsens must be kno...

Страница 8: ...device Pick up the device by holding it on the left and right edges only Note The switch is an indoor device If it is to be used with outdoor devices such as outdoor IP cameras or outdoor WiFi APs th...

Страница 9: ...g the Rubber Feet 4 2 Power Supply and Grounding Before the power supply cable is connected the device must be grounded Connect the grounding screw at the rear side with protective earth of the buildi...

Страница 10: ...ep 4 Check the system LED If it is on the power connection is correct Step 5 Ensure strain relief and defined cable routing for the RJ 45 wires Figure 9 DC Power Note When wiring the DC power input it...

Страница 11: ...single mode fiber or with versa That would cause increased damping back reflections or oversteering of the receiver SFP modules are hot pluggable You can install or remove a SFP from a slot without h...

Страница 12: ...as following Step 1 Connect the switch with your PC via an Ethernet interface Step 2 Open a WEB browser and enter the IP address of the switch You can find the IP address in the CLI interface or by ch...

Страница 13: ...hipped with the device to connect the COM port of your PC with the console port Step 2 Open a terminal program and configure the RS 232 settings Step 3 Press enter Now the CLI interface appears Step 4...

Страница 14: ...s Jumbo Frames 10K Flow Control Full Duplex IEEE 802 3x Half Duplex Back pressure Twisted pair Interface Number 4 part of combo ports 1 management port Type 10 100 1000Base T Connector RJ 45 shielded...

Страница 15: ...pid Spanning Tree IEEE 802 1s Multiple Spanning Tree IEEE 802 3ad Link Aggregation Control Protocol IEEE 802 1AB Link Layer Discovery Protocol 7 Disclaimer All information in this document is provided...