Media Converter/Signal Repeater
page 23/29
OID
Name
Access Description
1.3.6.1.4.1.20044.21.2.2.3.8.1
ms430580mAlmLine1TrscvAbsent
r
Line 1 SFP not plugged :This OID
indicates that the transceiver module 2 is
not present.
1.3.6.1.4.1.20044.21.2.2.3.8.2
ms430580mAlmLine1TrscvDdmAbsent
r
DDM supported on Line 1 SFP :This OID
indicates that the transceiver module 1
does not support Digital Diagnostic
Monitoring Functions
1.3.6.1.4.1.20044.21.2.2.3.8.4
ms430580mAlmLine1HwFail
r
Line 1 HW Failure :This OID indicates a
hardware failure on the Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.5
ms430580mAlmLine1TrscvLsd
r
Line 1 SFP optical TX ON :This OID
indicates the optical output power is off
on Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.9
ms430580mAlmLine1TrscvDdmWarning
r
Warning DDM on Optical Module 1: This
OID indicates a warning is present
coming out of optical interface DDM on
Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.10
ms430580mAlmLine1TrscvDdmAlm
r
Alarm DDM on Optical Module 1: This
OID indicates an alarm is present coming
out of optical interface DDM on Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.12
ms430580mAlmLine1Fail
r
Line 1 Failure: This OID indicates a
failure on the Line 1
1.3.6.1.4.1.20044.21.2.2.3.16
ms430580mAlmline1AccessioAlm
1.3.6.1.4.1.20044.21.2.2.3.16.1
ms430580mAlmLine1LasFail
r
Line 1 SFP Tx Failed: This OID indicates
that the transmitter fails for the
transceiver plugged into the Line 1 (this
alarm reports the transmitter failure
alarm generated by the transceivers)
1.3.6.1.4.1.20044.21.2.2.3.16.4
ms430580mAlmLine1Los
r
Loss of Optical signal on Line 1: This OID
indicates that no signal is present on the
transceiver 1
1.3.6.1.4.1.20044.21.2.3
ms430580mAlmLine
1.3.6.1.4.1.20044.21.2.3.1
ms430580mAlmLineNurg
1.3.6.1.4.1.20044.21.2.3.1.28
ms430580mAlmline2TrscvWarnDdm
1.3.6.1.4.1.20044.21.2.3.1.28.1
ms430580mAlmLine2TxPwLowWng
r
TRSCV 2 Tx Power Low warning:
Warning indicating that the transceiver
output power of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.2
ms430580mAlmLine2TxPwrHighWng
r
TRSCV 2 Tx Power High warning:
Warning indicating that the transceiver
output power of Line 2 is higher than
the threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.3
ms430580mAlmLine2TxBiasLowWng
r
TRSCV 2 Bias Low warning: Warning
indicating that the transceiver laser bias
current of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.4
ms430580mAlmLine2TxBiasHighWng
r
TRSCV 2 Bias High warning :Warning
indicating that the transceiver laser bias
current of Line 2 is higher than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.7
ms430580mAlmLine2TempLowWng
r
TRSCV 2 Temp Low warning:Warning
indicating that the transceiver
temperature of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
MICROSENS
GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com