Media Converter/Signal Repeater
page 17/29
−
Set to “on “the object: ms430580mCtrlColdReset
Location:
…\microsens\modulems430580m\ms430580mcontrolsWrite\ms430580mCtrlOther
\ms430580mCtrlswMgnt
Once this change is recognised the module starts to reset. Visual indication:
The colour sequence of the SW led on the front panel of the module during a reset is:
•
Green on > Red On > Green/Orange blinking > Green on
Under normal conditions all LEDs return to green when the reset is complete. The
status of the Line and Client Port LEDs depend on the local configuration. Refer to LED
status table. The duration of a Software Cold Reset on a MS430580M is approximately
25 seconds.
End procedure
Software Warm Reset
A warm reset only loads the selected software into the operational memory. This reset
has no effect on the traffic takes approximately 20 seconds to complete.
Procedure
•
Ensure that the correct module is selected for management. Consult the object:
−
mgnt2GigmSelectedBoard
Location:
…\microsens\mgnt2\mgnt2SNMPAgentData\ mgnt2ModulesManagement\
•
Change if necessary
•
Start the reset, set to “on “the object:
−
ms430580mCtrlWarmReset
Location:
...
\microsens\modulems430580m\ms430580mcontrolsWrite\ms430580mCtrlOther\m
s430580mCtrlswMgnt
Once this change is recognised the module starts to reset. Visual indications:
The colour sequence of the SW led on the front panel of the module during a Warm
Reset is:
•
Green on > Red on > Green on
Under normal conditions all LEDs return to green when the reset is complete. The
status of the Line and Client Port LEDs depend on the local configuration.
End procedure
Monitoring
In order to manage the various measurements available a polling mechanism is
required, thereby allowing the uploading of several physical parameters such as SFP
MICROSENS
GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com