NAME

DESCRIPTION

ACTION

ms430580mAlmLine2TxBiasLowWng

TRSCV 2 Bias Low warning:
Warning indicating that
thetransceiver laser bias current
ofLine 2 is lower than
thethreshold value written in the
transceiver EEPROM

Correlate all warnings. Carry out
necessary maintenance
procedures.

ms430580mAlmLine2TxBiasHighWng

TRSCV 2 Bias High warning:
Warning indicating that the
transceiver laser bias current of
Line 2 is higher than the threshold
value written in the transceiver
EEPROM

Correlate all warnings. Carry out
necessary maintenance
procedures.

ms430580mAlmLine2TempLowWng

TRSCV 2 Temp Low warning:
Warning indicating that the
transceiver temperature of Line
2 is lower than the threshold
value written in the transceiver
EEPROM

Correlate all warnings and
Alarms.
Carry out necessary maintenance
procedures.

ms430580mAlmLine2TempHighWng

TRSCV 2 Temp High warning:
Warning indicating that the
transceiver temperature of Line
2 is higher than the threshold
value written in the transceiver
EEPROM

Correlate all warnings. Carry out
necessary maintenance
procedures.

ms430580mAlmLine2RxPwrLowWng

TRSCV 2 Rx Power Low warning:
Warning indicating that the
transceiver input power
of Line 2 is lower than the
threshold value written in the
transceiver EEPROM

Correlate all warnings. Carry out
necessary maintenance
procedures.

ms430580mAlmLine2RxPwrHighWng

TRSCV 2 Rx Power Highwarning:
Warning indicating that the
transceiver input power
of Line 2 is higher than the
threshold value written in the
transceiver EEPROM

Correlate all warnings. Carry out
necessary maintenance
procedures.

ms430580mAlmLine2CdrLossofsignal

Line 2 CDR Loss of Signal: This OID
indicates that a Lossof electrical
signal is detectedon the Line 2
CDR

Check client status. Carry out
necessary maintenance
procedures.

ms430580mAlmLine2CdrLossoflock

Line 2 CDR Loss of Lock: This
OID indicates that the Line 2
CDR is not locked

Check client status. Carry out
necessary maintenance
procedures.

ms430580mAlmLine2CdrRefAbsent

Line 2 CDR Reference clock
absent: This OID indicates that
the CDR reference clock is
absent on Line 2

No action information only.

ms430580mAlmLine2TxPwrLowAla

TRSCV 2 Tx Power Low: Alarm
indicating that the transceiver
output power of Line 2 is lower
than the threshold value written
in the transceiver EEPROM

Correlate all. Carry out necessary
maintenance procedures.

ms430580mAlmLine2TxPwrHighAla

TRSCV 2 Tx Power High: Alarm
indicating that thetransceiver
output power ofLine 2 is higher
than thethreshold value written in
thetransceiver EEPROM

Correlate all Alarms. Carry out
necessary maintenance
procedures.

MICROSENS

 GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com

Содержание Media Converter/Signal Repeater Module

Страница 1: ...management card Max 5x single size modules f ex 2x double size 1x single size module Hot swappable modules power supplies Redundant power supplies with 48 VDC input opt 230 VAC Exchangeable air and fi...

Страница 2: ...rface Digital Diagnostic Monitoring information from SFP System description The block diagram for the MS430580M is given in Figure 1 The MS430580M is a bi directional device that offers twice the same...

Страница 3: ...type used on Line 1 and Line 2 it is possible to perform together with the signal regeneration a media convertion 850nm to 1310nm CWDM to DWDM etc The following alarms are provided to the controller...

Страница 4: ...a microprocessor associated with Flash and RAM memories The controller block collects information from different functional blocks and configures the HW according to a configuration file received The...

Страница 5: ...580mConfig ms430580mCfgStartup ms430580mtableclientStartup The following table details the meaning of each bit as well as the default values ms430580mCfgportaTrscvCtrl Bit Default value Bit Name Descr...

Страница 6: ...Description Bit 3 0 0000 Line 1 and Line 2 bitrate Bitrate selection 0 2 488 Gb s OC 48 STM16 1 1 25 Gb s GbE 2 622 08 Mb s OC 12 STM4 3 155 52 Mb s OC 3 STM1 4 2 125 Gb s 2GFC 5 1 0625 Gb s 1GFC 7 12...

Страница 7: ...configuration from the SNMP agent to the modules RAM Transfer the new configuration into the module using the object ms430580mCtrlConfFlash Location microsens modulems430580m ms430580mcontrolsWrite m...

Страница 8: ...AAA01 Release date yymmdd 060509 SW Part Number 3SW07001AAAA Version Number 02 Release date yymmdd 060510 ms430580mRinvPortASFP This object returns information relating to the Line 1 SFP in the Module...

Страница 9: ...tenance procedures ms430580mAlmLine1TxBiasLowWng TRSCV 1 Bias Low warning Warning indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transcei...

Страница 10: ...threshold value written in the transceiver EEPROM Correlate all Alarms Carry out necessary maintenance procedures ms430580mAlmLine1TxBiasLowAla TRSCV 1 Bias Low Alarm indicating that the transceiver...

Страница 11: ...s ms430580mAlmLine1TrscvDdmAlm Alarm DDM on Optical Module 1 This OID indicates an alarm is present coming out of optical interface DDM on Line 1 Correlate all alarms Carry out necessary maintenance p...

Страница 12: ...in the transceiver EEPROM Correlate all warnings Carry out necessary maintenance procedures ms430580mAlmLine2RxPwrHighWng TRSCV 2 Rx Power Highwarning Warning indicating that the transceiver input po...

Страница 13: ...edures ms430580mAlmLine2RxPwrHighAla TRSCV 2 Rx Power High Alarm indicating that the transceiver input power of Line 2 is higher than the thresholdvalue written in the transceiverEEPROM Correlate all...

Страница 14: ...nchronous event that the MGNT generates to indicate a status change e g a trap is generated on the detection of a start of an alarm and an end of an alarm Note It is important to set the IP address of...

Страница 15: ...Carry out necessary maintenance procedures ms430580mPortbTrapNotUrgentGoesOff Not urgent Line 2 fault disappeared ms430580mAlmPortbTrscvDdmWarning ms430580mtrapBoardNumber No Action ms430580mPortbTrap...

Страница 16: ...nt2 mgnt2SNMPAgentData mgnt2ModulesManagement Note Use the MS module series chassis User Manu al SNMP for details about this OID Using a flat head screwdriver tighten the holding screw on the frontpla...

Страница 17: ...imately 20 seconds to complete Procedure Ensure that the correct module is selected for management Consult the object mgnt2GigmSelectedBoard Location microsens mgnt2 mgnt2SNMPAgentData mgnt2ModulesMan...

Страница 18: ...gged into Line 1 and Line 2 read from the Digital Diagnostic Monitoring Unit C The following formula must be applied to the returned value in order to obtain the actual temperature T C MSB LSB 256 Par...

Страница 19: ...3 3094V Bias The object ms430580mMesrportaTxBias Location microsens modulems430580m ms430580mmeasures ms430580mMesrClient The object ms430580mMesrportbTxBias Location microsens modulems430580m ms43058...

Страница 20: ...le A listing of the ms430580mMesrportaTxPower outputs the following SNMP QUERY STARTED 1 ms430580mMesrportaTxPower integer 30 SNMP QUERY FINISHED The value returned from the SFP in Line 1 is 30 So app...

Страница 21: ...tual value of 0 001mW And applying the formula Rx_Pwr dBm 10xlog 10 10000 Gives an actual value of 30dBm Appendixes Laser Class Laser Class Risks General Requirements 1 Considered safe to eye and Skin...

Страница 22: ...shold value written in the transceiver EEPROM 1 3 6 1 4 1 20044 21 2 2 1 20 2 ms430580mAlmLine1TxPwrHighWng r TRSCV 1 Tx Power High warning Warning indicating that the transceiver output power of Line...

Страница 23: ...is alarm reports the transmitter failure alarm generated by the transceivers 1 3 6 1 4 1 20044 21 2 2 3 16 4 ms430580mAlmLine1Los r Loss of Optical signal on Line 1 This OID indicates that no signal i...

Страница 24: ...6 1 4 1 20044 21 2 3 2 ms430580mAlmLineUrg 1 3 6 1 4 1 20044 21 2 3 2 26 ms430580mAlmline2TrscvAlmDdm 1 3 6 1 4 1 20044 21 2 3 2 26 1 ms430580mAlmLine2TxPwrLowAla r TRSCV 2 Tx Power Low Alarm indicat...

Страница 25: ...r Warning DDM on Optical Module 2 This OID indicates a warning is present coming out of optical interface DDM on Line 2 1 3 6 1 4 1 20044 21 2 3 3 7 10 ms430580mAlmLine2TrscvDdmAlm r Alarm DDM on Opt...

Страница 26: ...value of the transceiver Line 2 read from the DDM Digital Diagnostic Monitoring Unit mA 1 3 6 1 4 1 20044 21 3 3 27 ms430580mMesrline2TxPower r Line 2 SFP Transmitted Power This OID gives the transmit...

Страница 27: ...rscvOnoff r w Line 1 SFP Optical Laser OFF This OID switches off the transceiver on Line 1 1 3 6 1 4 1 20044 21 6 3 ms430580mCtrlLine 1 3 6 1 4 1 20044 21 6 3 24 ms430580mCtrlline2TrscvOnoff 1 3 6 1 4...

Страница 28: ...e1TrapNotUrgentGoesOff n a Not urgent Line 1 default disappeared 1 3 6 1 4 1 20044 21 10 32 ms430580mLine1TrapUrgentGoesOn n a Urgent Line 1 default is activated 1 3 6 1 4 1 20044 21 10 33 ms430580mLi...

Страница 29: ...al lost Fail Transmission failure Power consumption 8 W typical 10 W max Operating temperature 0 C to 50 C Storage temperature 20 C to 85 C Order Information Art No Description Connectors MS430580M 3R...