DOC 4380A
4380A O & M Manual
57
098-00723-000
– Jul 2017 Revision 4.0
SyncSystem 4380A O&M Manual
[ports]
[1]
[2]
[3]
[4]
[5]
[empty]
[6]
[4387]
[ports]
[1]
[2]
[3]
[4]
[ptd_port]
[averaging_interval] 10
[reference]
[external]
[type] hp5071a
[source] external
[smcp]
[syscfg]
[mode] standalone
[OK] 2015-08-08T14:31:37Z
V.
At this point if there are no alarms the 4380A is functioning properly. Network connectivity
should be checked to ensure that data is being transmitted properly.
W.
Log files will be available to the ftp user after the specified log period has expired as long as the
ftp logging is enabled. If in the auto positioning mode the rinex file will be available after the
auto_positioning period has expired. The real-time logs will be available on Port 1135.
X.
TIC Measurements will be available (Raw = 2101, Avg = 2100) if one or more 4393A cards are
installed and there are 1PPS signals detected on the input ports.
Y.
If operations are normal and the setup is proper type
save
at the command prompt to save the
system default settings or
save filename
to save the settings to a different configuration file. Use
the
save_logs ftp
and
save_logs rt
commands to save the ftp or real time logging default settings
or add a filename to these commands to save the settings to a different configuration file.
Note:
If you do not save the user
default
settings the system will come up with the
factory default
values the next time the system reboots or is power cycled.