DOC 4380A
4380A O & M Manual
42
098-00723-000
– Jul 2017 Revision 4.0
SyncSystem 4380A O&M Manual
jam_sync
Synchronizes the system 1 PPS to the reference input.
pps
Allows the operator to set the PPS parameters on the 4394A and 4394A-
ECL Cards.
nasa36
Allows the operator to enable the Nasa36 time code on the selected
4387A (AM IRIG) card port.
t1
Allows the operator to select one of four operating modes on the 4374A
(T1) card ports.
Bit Code Commands
4331/4391 Cards only
bitcode_list
List bit code file names and sizes
bitcode_clock
Configure a code generator module clock
bitcode_memblock
Assign a file to a code generator module memory block
bitcode_port
Configure a code generator module port
bitcode_stream
Configure a code generator module stream
Time Zone Commands
4334/4337 Cards only
tz_update
Allows users to load or clear out the time zone database
tz_list
Allows users to list the contents of the time zone database.
System Commands
clear_alarms
Clears latched alarm events.
firewall
Configures system firewall.
frontpanel_button
Enables(1) or disables (0) the front panel button from resetting the units
IP address if held in for ~10Seconds.
hostname
Allows user to change domain / hostnames.
leapfile
Allows users to load a leap second file on the unit.
network_config
Set up network settings. [--mode DHCP|static] [--ip <ip>] [--mask
<netmask>] [--broadcast <broadcast>] [--gateway <gateway>]
prompt
Allows the operator to change the command prompt for the current
session or make the changes part of the system default settings.
ptdavg
Allows the user to set the averaging interval (in seconds) for the TIC
cards installed in the unit. Valid intervals are 1, 10, 20, 60 and 300
seconds.
reboot
Reboots the 4380A
restart
Restarts the application without rebooting the system
software_update
Execute the software update routine.
syscfg
System Configuration commands
Other Commands
remote_ntp_offset
Returns the offset in seconds between Sync System time and that of an
external NTP server
Table 5 System Command List
Access to the 4380A command port is available via telnet (Port 1700) and through the USB Ports located
on the back of the unit via the 94000-115200 Console Cable. The 4380A is a DTE device utilizing the
RS232 communication protocol. Settings for the port are 115,200 baud, 8 data bits, 1 stop bit, no parity,
and no flow control. It is sometimes necessary to access the system via the USB port because the 4380A
may not be accessible via the network until the IP Address has been set.
3.4.1.3 Diagnostic Port (1800)
The 4380A provides an IP port to aid in diagnosing system errors. Each of the subsystems within the
4380A provides diagnostic output that can aid in identifying system errors. It is typically not necessary for
users to access the diagnostic port because all system errors are reported on the front panel (Alarm Light),
in the alarms list (
status alarm
) and/or can be recovered using the
syslog
command.
Diagnostic messages are only displayed on the diagnostic port. If users wish to save the messages provided
by the diagnostic port then the output of this port must be saved to a file. It is recommended that diagnostic
Содержание SyncSystem 4380A
Страница 2: ......