DOC 4380A
4380A O & M Manual
33
098-00723-000
– Jul 2017 Revision 4.0
SyncSystem 4380A O&M Manual
[set]
[what] Incorrect format in slot 6 port 2: expected=B, actual=H
[when] 2013-09-05-23:53:16.800
[OK] 2013-09-05T23:55:35Z
To get a complete list of the configuration errors use the
status syscfg:errors
command.
4380A>status syscfg:errors
[1] Incorrect format in slot 6 port 2: expected=B, actual=H
[2] Incorrect signal word in slot 6 port 2: expected=120, actual=121
[OK] 2013-09-05T23:56:38Z
To stop using this feature use:
4380A>syscfg --mode standalone
Set Mode
[OK] 2013-09-05T23:53:17Z
Once the system has been set up for the correct mode use the
save
command to save the current system
settings and the system will use these settings after a power cycle, restart, or reboot.
2.11
Powering the System Off
To remove power from the 4380A remove the input power sources from Power Supply #1 and #2.