background image

SyncServer S80 NTP User Guide

098-00777-000 Rev. A

17

Figure 2-6 • 

SyncServer S80 Dimensions

Figure 2-7 • 

Mounting Kit for SyncServer S80

Содержание SyncServer S80

Страница 1: ...SyncServer S80 NTP Server User Guide Part Number 098 00777 000 Revision A...

Страница 2: ...SyncServer S80 NTP Server...

Страница 3: ...mands 27 Using CLI Commands 27 S80 CLI Command Conventions 27 CLI Command Keyboard Usage 27 Command Line Format 27 Command User Levels 27 S80 Command Set 28 show alarm 29 show alarm config 30 set alar...

Страница 4: ...v2 Traps 56 Provisioning to Generate v3 Traps 56 Adding and Removing v2 Communities 57 Adding and Removing SNMP v3 Users 57 Provisioning for LLDP 58 LLDP Implementation in S80 58 5 Troubleshooting 61...

Страница 5: ...Table of Contents 5 November 2017 Customer Assistance Center 73 Technical Support 73 Website 73 Contacting the Customer Assistance Center 73 Email 73 Outside the U S 74...

Страница 6: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 6...

Страница 7: ...tionary or moving platforms Mounting hardware included Software Option The SyncServer S80 includes built in hardware features enabled via software license key 1000 NTP requests per second Activation k...

Страница 8: ...Overview 8 098 00777 000 Rev A bottom of the unit See Figure 1 1 Figure 1 1 RJ45 Port on SyncServer S80...

Страница 9: ...nts The SyncServer S80 requires the following for proper installation and function Mounting site outdoors with GNSS satellites visibility Network connection with 1 Gigabit Ethernet capacity Power thro...

Страница 10: ...Installation of SyncServer S80 10 098 00777 000 Rev A Figure 2 1 SyncServer S80 Connection Diagram...

Страница 11: ...ccessories 9 Verify that the model and item number shown on the shipping list agrees with the model and item number on the equipment The item number can be found on a label affixed to the bottom of th...

Страница 12: ...or PoE should be isolated It needs to a be single port injector such as Microsemi s PD 9001G 40 SP Midspan The Primary surge protection device needs to be as close as possible to inlet to the building...

Страница 13: ...oor PoE Power Requirements The SyncServer S80 receives power through Power Over Ethernet PoE The Power input to the unit needs to be PoE Class 3 Network Connection The Ethernet port available through...

Страница 14: ...cServer S80 because there is no convenient method for retrieving assigned DHCP address for the management port after reboot 5 Set the desired IPv4 or IPv6 address using the set ip command IPv4 Example...

Страница 15: ...nd washer from the Installation Kit 093 00741 000 11 Screw the first pipe nut onto the bottom of the mounting pole as shown in Figure 2 11 12 Attach the mounting bracket 093 00001 01 to the bottom of...

Страница 16: ...hird customer supplied Ethernet cable to the Output end of the power injector or POE midspan repeater as shown in Figure 2 1 26 Plug a second Ethernet cable into an unpowered Ethernet port on your net...

Страница 17: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 17 Figure 2 6 SyncServer S80 Dimensions Figure 2 7 Mounting Kit for SyncServer S80...

Страница 18: ...Installation of SyncServer S80 18 098 00777 000 Rev A Figure 2 8 Installation Bracket for SyncServer S80...

Страница 19: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 19 Figure 2 9 Cable Routing Before Final Assembly...

Страница 20: ...Installation of SyncServer S80 20 098 00777 000 Rev A Figure 2 10 Connecting Customer Cable to Antenna Detail Sealant Strip...

Страница 21: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 21 Figure 2 11 Attaching SyncServer S80 to Pole...

Страница 22: ...Installation of SyncServer S80 22 098 00777 000 Rev A Figure 2 12 Attaching SyncServer S80 and Pole to Bracket...

Страница 23: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 23 Figure 2 13 Mounting SyncServer S80 to a Mast Figure 2 14 Mounting SyncServer S80 to a Vertical Surface...

Страница 24: ...Installation of SyncServer S80 24 098 00777 000 Rev A Figure 2 15 Surge Protector Dimensions...

Страница 25: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 25 Figure 2 16 Connecting Surge Protector...

Страница 26: ...Installation of SyncServer S80 26 098 00777 000 Rev A Figure 2 17 Mounting Surge Protector on Pole Figure 2 18 Mounting Surge Protector on Outdoor Wall...

Страница 27: ...is a prompt for you to press ENTER to execute the command that you entered The SHIFT QUESTION MARK accesses the CLI online help It can be used at any time while typing a command including at the prom...

Страница 28: ...es an alphabetical listing and details of all CLI commands that are available while in CLI mode The list below provides a summary of all CLI commands show alarm show alarm config set alarm config show...

Страница 29: ...w alarm Level User Config and Admin Example S80 show alarm Response Alarms Date Time ID index Severity Descriptions 2017 04 17 11 48 55 098 index 000 ALARM SEVERITY EVENT GNSS PPS failed 2017 04 17 11...

Страница 30: ...ications failed 92 Minor enable 0 GNSS receiver not tracking satellite 98 Event enable 0 GNSS PPS failed 99 Event enable 0 GNSS Base Config failed 111 Minor enable 0 Ethernet port link down 112 Minor...

Страница 31: ...larm config delay alarm 1 to 163 all value 0 to 500000 Level Config and Admin Example 1 To Disable alarm S80 set alarm config state alarm 5 disable Example 2 To set the severity level of alarm 5 to ma...

Страница 32: ...bridge time Response Bridging Time 300 Note If the system has not qualified a time or frequency reference within the specified bridging time the system transitions into holdover mode of operation set...

Страница 33: ...clock Response System time Tue Apr 18 11 32 49 2017 Leap Seconds 36 Leap pending 0 set clock Provisions the user assigned Date Time and accumulated leapseconds Command Syntax To set the Date and Time...

Страница 34: ...to set the current configuration to factory settings Factory removes all attributes Use of this command results in reboot of the S80 Command Syntax set configuration factory Level Config and Admin Ex...

Страница 35: ...e 1a GNSS Configuration GNSS Status enable elevation_mask 7 Track Mode gps Pos Mode auto Antenna Delay 0 GNSS manual position Latitude N37 22 43 425 Longitude W121 55 34 815 Height 13 7 Response 1b GN...

Страница 36: ...le delay and the elevation mask the angle below which the satellites are not used by the system It allows the user set the track mode for GPS only disable or GPS GLONASS enable This command also allow...

Страница 37: ...cable delay 200 Example 4 To set the position mode to auto S80 set gnss posmode auto Example 5 To set the track mode to GPS only S80 set gnss track mode glonass disable show hostname This command disp...

Страница 38: ...umber Clei Number Serial Number Software ver Hardware Ver Fpga Ver Mac address Manufacturing status Pcba Command Syntax show inventory Level User Config and Admin Example S80 show inventory Response p...

Страница 39: ...runs 0 frame 0 TX packets 23369349 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 35465171789 35 4 GB TX bytes 19857282436 19 8GB Example 2 S80 show ip config Response 2...

Страница 40: ...2001 0db8 0000 0000 0000 ff00 0042 8329 After removing all leading zeroes in each group 2001 db8 0 0 0 ff00 42 8329 After omitting consecutive sections of zeroes 2001 db8 ff00 42 8329 Command Syntax T...

Страница 41: ...y 1234567890abcdefghij09875654321klmnopqrst S80 set license add 1234567890abcdefghij09875654321klmnopqrst Note After three unsuccessful attempts user can t add license for a block out period of 15mins...

Страница 42: ...w log This command displays the specified log file content from the local storage When showing the log content the Index parameter selects one of the seven rotated log files The Head parameter along w...

Страница 43: ...8 11 40 11 S80 local5 info syslog user root show alarm config Apr 18 11 45 02 S80 local5 info syslog user root show log alarm event file index 0 head 10 Example 3 S80 show log diag state Response 3 Di...

Страница 44: ...ion and status of NTP for the unit Command Syntax show ntp config status Example 1 S80 show ntp config Response 1 NTP status Enabled IP version IPv4 TTL 64 DSCP 46 Max Packets 500 Alarm Threshold 100...

Страница 45: ...Level User Config and Admin Note Each user level can change its own password Additionally admin user can modify config and user passwords Example S80 password user Response Changing password for user...

Страница 46: ...ot Response S80 reboot System is going to reboot The system is going down NOW Sent SIGTERM to all processes TERM Sent SIGKILL to all processes Requesting systRestarting system U Boot 2010 03 00002 gb9...

Страница 47: ...community To show SNMP trap version information show snmp trapversion To show SNMP v2 state show snmp state v2 Example 1 S80 show snmp manager Response 1 SNMP engineID 0x80001f880300b0ae03e376 Trap IP...

Страница 48: ...an SNMP trapuser set snmp delete trapuser name To delete an SNMP manager set snmp delete manager ip address Example 1 S80 set snmp trapversion 3 Example 2 S80 set snmp add manager 192 168 1 100 Exampl...

Страница 49: ...ency Status FREERUN Frequency State Duration min 216 Clock Time Status FREERUN Time State Duration min 216 Currently Selected Frequency reference NONE Currently Selected Timing reference NONE Frequenc...

Страница 50: ...CLI Commands 50 098 00777 000 Rev A...

Страница 51: ...cribes how to test the S80 unit before deployment Overview Establishing a Connection to the S80 Configuring the IP Address DHCP Mode Static IP Mode Managing the User Access List Setting GNSS Parameter...

Страница 52: ...re to configure the S80 to enable DHCP on the MGMT port Example 1 Login at the Admin or Config user level see Logging In on page 53 2 Type set ip ipv4 address mode dhcp and press Enter Caution If you...

Страница 53: ...ble 4 1 1 Login with the Admin name level see Logging In on page 215 2 For admin type password admin and press Enter For config type password config and press Enter For user type password user and pre...

Страница 54: ...er 5 Type set ntp dscp 45 and press Enter 6 Type set ntp alarmthresh 90 and press Enter Setting the System Date and Time The S80 Time of Day can be set either by an external source or manually with th...

Страница 55: ...user level see Logging In on page 215 2 Type set alarm config state alarm 33 disable and press Enter Showing Current Alarm Settings The Show Alarm Config command displays the set and clear alarm thre...

Страница 56: ...rt SNMP functionality is provisioned on the S80 using the CLI command set snmp see Figure 4 30 Each alarm trap OID from the S80 represents a unique alarm Each container contains the following sub info...

Страница 57: ...nd to add a v3 user Use the set snmp delete user command to remove an existing v3 user The S80 will support a maximum of ten v3 users Example Add User To add a user named test12 with a security level...

Страница 58: ...erval in the form of an Ethernet frame Each frame contains one LLDP Data Unit LLDPDU Each LLDPDU is a sequence of type length value TLV structures The Ethernet frame used in LLDP has its destination M...

Страница 59: ...Rev A 59 Example 2 To set the LLDP state to enable S80 set lldp enable Example 3 S80 show lldp config Response 3 LLDP State enable Below is a screenshot from Wire Shark which shows typical LLDP frames...

Страница 60: ...Configuration 60 098 00777 000 Rev A...

Страница 61: ...ate Transitioned out of warm up state No action required No action required Entered time frequency free run state 002 Minor No Enteredtime frequency free run state Transitioned out of free run state N...

Страница 62: ...021 Minor No GNSS input assessing If this persists for 1hr check input reference For GNSS check signal quality GNSS input time qualified 022 Event No GNSS input time qualified No action required GNSS...

Страница 63: ...connected properly Installation should conform to the guidelines as described in Ch 2 No action required GNSS PPS failed 98 Event No GNSS PPS failed GNSS Base Config failed 99 Event No GNSS Base Conf...

Страница 64: ...ared If alarm persists power cycle reboot Call SGS support if it persists after reboot power cycle No action required Temperature out of range 139 Minor No Temperature out of range Temperature out of...

Страница 65: ...g the product If the original packaging is not available contact Microsemi FTD Services and Support for assistance Repacking the Unit Return all units in the original packaging If the original packagi...

Страница 66: ...numbers clearly marked on the outside of the container to the address given with the RMA Repaired equipment is returned to you with shipping costs prepaid by Microsemi User s Guide Updates When this m...

Страница 67: ...arameter Specification Mounting Roof Diameter 6 0 inches 15 24 cm Height 6 0 inches 15 24 cm Weight 1 5 lbs 0 68 kg Table A 2 Environmental Specification Parameter Specification Operating Temperature...

Страница 68: ...S Class B limits VCCI V 3 2015 04 V 4 2012 04 Class B limits KN 55032 35 Class B limits K 20 BSMI EMC Certifications EMC Directive 2014 30 EU Class B FCC part 15 ICES 003 VCCI AS NZS CISPR 22 ETSI EN...

Страница 69: ...speed 45 miles hour Table A 7 Output Specification Parameter Specification NTP NTP v3 v4 mode 3 NTP client time requests 500 NTP requests per second optionally 1000 NTP requests per second Stratum 1 t...

Страница 70: ...8 2 100 Valid IPv4 address IPv4 Network Mask 255 255 255 0 Valid IPv4 mask IPv4 Network Gateway 192 168 2 1 Valid IPv4 Address where value of 0 0 0 0 is used for no gateway IPv6 Network Address Valid...

Страница 71: ...e Trap Manager IPv4 0 0 0 0 Up to 15 character IPV4 address string Trap Version 2 2 3 V2 Trap Commnunity public Up to 19 character string V3 Secure Level noauth 0 1 2 0 noauth 1 auth 2 priv V3 Auth Pa...

Страница 72: ...Log Configuration Parameters Table A 13 Log Configuration Parameters Parameter Value Default Value Range Size for Alarm Event Log kb 100 1 to 100 Size for Command Log kb 100 1 to 100 Size for Securit...

Страница 73: ...ation notes answers to common design cycle questions documentation of known issues and various FAQs So before you contact us please visit our online resources It is very likely we have already answere...

Страница 74: ...ude high performance and radiation hardened analog mixed signal integrated circuits FPGAs SoCs and ASICs power management products timing and synchronization devices and precise time solutions setting...

Отзывы: