SyncServer S80 NTP User Guide
098-00777-000 Rev. A
15
Installing the SyncServer S80 Outdoors
Use the following procedure to install the SyncServer S80 outdoors. Typical installation requires
mounting and grounding two surge protectors. The first surge protector should be mounted as close as
possible to the SyncServer S80. The second surge protector should be mounted in the entrance to the
indoor building.
1. Identify the outdoor location for mounting the SyncServer S80 unit.
2. Guide the customer-supplied waterproof 12-inch CAT
7
Ethernet cable and RJ-45 connector of the
SyncServer S80 through the bottom of the mounting pole (070-02006-000). As partially shown in
, the cable must first pass through a pipe nut, then the mounting bracket, then through
the second pipe nut.
3. Remove the nut on the Ethernet System and loosen the feed-thru seal, as shown in
4. Guide the customer-supplied cable through the feed-thu seal and other components of the
Ethernet system, as shown in
5. Remove the plastic from both sides of the sealant. Place and mold the sealant around the
customer-supplied cable, as shown in
6. Plug the RJ45 connector of the customer-supplied CAT7 cable into the Ethernet port of the
SyncServer S80, as shown in
7. Screw the end of the Ethernet system into the Antenna connector housing, as shown in
.
8. Reassemble the Ethernet system, and tighten the feed-thru seal, as shown in
.
9. Gently pull the customer-supplied cable at the opposite end of the mounting pole to remove any
slack, sliding the Ethernet system into the top of the mounting pole. Continue until the top of the
mounting pole fits into the Antenna.
10. Attach the SyncServer S80 unit to the top of the mounting pole, and secure it using the screw and
washer from the Installation Kit (093-00741-000).
11. Screw the first pipe nut onto the bottom of the mounting pole, as shown in
.
12. Attach the mounting bracket (093-00001-01) to the bottom of the mounting pole, as shown in
. Screw the second pipe nut onto the bottom of the mounting pole.
13. If mounting the SyncServer S80 to a mast, attach the mounting bracket to the pole with the
14. If mounting to a vertical surface, attach the mounting bracket with the included screws, as shown
. Adhere to local building codes to determine the type and number of fasteners,
screws, bolts, etc. that may be required.
15. Mount the surge protector to the mast or vertical surface on which the SyncServer S80 is
mounted., close to the unit. See
for surge protector dimensions.
16. If mounting to a mast, first remove the bracket by unscrewing both of its screws. Attach the surge
protector to the mast using a worm gear clamp. See
.
17. If mounting to a vertical surface use the attached bracket on the surge protector and mounting
screw to attach to the unit to the surface. See
for an example of mounting the unit to
a vertical surface with the bracket.
18. Plug the other end of the customer-supplied waterproof 12-inch CAT
7
Ethernet cable into the
"Line" end of the surge protector. See
for details about connecting to the surge
protector.
19. Plug the second customer-supplied waterproof CAT
7
Ethernet cable into the "Equip" end of the
surge protector. See
for details about connecting to the surge protector.
20. Ground the surge protector unit using the GND screw and strap.
21. Mount the second surge protector at the point where the cable enters the building. See
for an example.
22. Plug the other end of the second customer-supplied waterproof CAT
7
Ethernet cable into the
"Line" end of the second surge protector. See
for details about connecting to the
surge protector.
Содержание SyncServer S80
Страница 1: ...SyncServer S80 NTP Server User Guide Part Number 098 00777 000 Revision A...
Страница 2: ...SyncServer S80 NTP Server...
Страница 6: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 6...
Страница 10: ...Installation of SyncServer S80 10 098 00777 000 Rev A Figure 2 1 SyncServer S80 Connection Diagram...
Страница 18: ...Installation of SyncServer S80 18 098 00777 000 Rev A Figure 2 8 Installation Bracket for SyncServer S80...
Страница 19: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 19 Figure 2 9 Cable Routing Before Final Assembly...
Страница 21: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 21 Figure 2 11 Attaching SyncServer S80 to Pole...
Страница 22: ...Installation of SyncServer S80 22 098 00777 000 Rev A Figure 2 12 Attaching SyncServer S80 and Pole to Bracket...
Страница 24: ...Installation of SyncServer S80 24 098 00777 000 Rev A Figure 2 15 Surge Protector Dimensions...
Страница 25: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 25 Figure 2 16 Connecting Surge Protector...
Страница 50: ...CLI Commands 50 098 00777 000 Rev A...
Страница 60: ...Configuration 60 098 00777 000 Rev A...