Workstation 5 Field Service Guide
3-27
Workstation 5 Troubleshooting
Touchscreen Related
Touchscreen Related
This section includes several touchscreen related symptoms and applies only to
the ABRD88 system board. Note that a POST for the touchscreen interface and
controller is not implemented.
Touchscreen Not Responding after the Operating System Starts
Symptoms: The Workstation 5 starts Windows Embedded CE 6.0, but the
touchscreen does not respond. No error messages are reported.
•
Restart the Workstation. Do not touch the screen until after the unit boots to
the CE Desktop.
o
The current Windows Embedded CE 6.0 touch screen driver has a
known issue where if the user touches or cleans the touchscreen while
WinCE boots, it fails to detect touches after WinCE displays the
desktop.
•
If the touchscreen does not function after allowing the system to boot
without touching the screen, see below.
o
Defective, damaged, or pinched interface cable. Check the cable at the
point where it mounts to the glass surface.
o
Defective touchscreen interface U17/U19.
o
Damaged EMI Protection Circuit - Check D8 through D12.
Touchscreen Calibration
Symptoms: After booting, touches appear on the screen, but the calibration is
such that you cannot access the desktop calibration icon.
•
Defective, damaged, or pinched interface cable. Check the cable at the
point where it mounts to the glass surface.
•
Connect a USB Keyboard/Mouse combo and start the ‘TSHARC
Calibration’ utility on the desktop.
o
Run through the calibration procedure, touching and holding each
target, and releasing when prompted. If touchscreen calibration is not
acceptable after completing the procedure, see below.
•
Defective Touchscreen glass.
•
Incorrect configuration jumper settings.
o
The Workstation 5 supports a Capacitive Touchscreen, but as of
February 2009 this option has not entered production. If the
configuration jumpers are missing or set incorrectly, the symptoms may
appear as a calibration issue instead of a ‘no response to touch.’
message. Refer to Figure 3-9 to make sure the jumpers are set correctly.
Note that Pin 1 of the jumper block faces the IO Panel.
Содержание Workstation 5
Страница 112: ...3 44 Workstation 5 Field Service Guide Workstation 5 Troubleshooting WS5 Diagnostic...
Страница 155: ...Workstation 5 Setup Guide B 13 Connector and Cable Diagrams Hook up Cables Cash Drawer Extension Cable...
Страница 156: ...B 14 Workstation 5 Setup Guide Connector and Cable Diagrams Hook up Cables...