Beschreibung der einzelnen Menüpunkte
4-6
PAPER EXTENDED
With
PAPER EXTENDED
set to
NO
printing into the border areas of
A4
and
LETTER
pages is not possible which is in line with the PCL5 definition. However,
for compatibility to existing applications which use the border areas
PAPER
EXTENDED
can be set to
YES
. Now the entire physical page is printable at which
the default cursor position remains unchanged.
With format CUSTOM the complete page can also be printed but the default
cursor position is always the first dot at the upper left corner.
PAPER SELECTION
Selecting the paper format (A4, LETTER, CUSTOM) from the host can be done
with PCL or PJL commands. The execution of these commands can be influenced
by the parameter PAPER SELECTION.
RECOGNIZE
–
A change of
PAPER
is possible via interface by means of
PCL- or PJL-commands.
ONLY PJL
– Only via PJL-command (default)
IGNORE
– Any command to change the paper format will be ignored;
the paper format can only be modified via the operator panel.
Note:
PAPER SELECTION
by the printer driver needs the setting
RECOGNIZE
or
ONLY PJL
.
The
F44
printer driver for Windows
7
uses PCL and PJL sequences.
.
FUSER TEMP.
(Fuser Temperature)
This parameter allows adapting the fuser temperature to media properties.
Default level is
MIDDLE
(about 200° C).
Other selections are:
─
HIGH
(for thick paper, labels, and in conjunction with MICR; about 230° C)
─
LOW
(for thin paper and labels; about 170° C)
─
XLOW
(for very thin paper and sensitive labels; about 150° C)
Fuser temperature adjustment is necessary when temperature sensitive form sets
(e.g. labels) are printed.
HUMIDITY
Since the paper depending on storage, the moisture takes the environment, with
this parameter; the amount of humidity can be set.
The possible values are:
NORMAL
(default)
HIGH
The printer is sensitive to different environmental temperatures. He provides the
best performance however with a temperature of 19 ° to 23 ° C (68 ° to 73 ° F)
with relative humidity 33 up to 47%.
For higher humidity values, the parameter should be set
HIGH
.
Note:
In
Chapter 8 Paper Specification
there is a detailed description of the
humidity content and storage of the paper.
Содержание SOLID F44
Страница 1: ...User s Manual SOLID F44...
Страница 131: ...B 1 Appendix B Symbol Sets Roman 8 Display ROMAN 8 ID Number 8U...
Страница 132: ...Appendix B Symbol Sets B 2 ISO 8859 1 Latin 1 Display ISO L1 ID Number 0N...
Страница 133: ...Appendix B Symbol Sets B 3 ISO 8859 2 Latin 2 Display ISO L2 ID Number 2N...
Страница 134: ...Appendix B Symbol Sets B 4 ISO 8859 9 Latin 5 Display ISO L5 ID Number 5N...
Страница 135: ...Appendix B Symbol Sets B 5 ISO 8859 15 Latin 9 Display ISO L9 ID Number 9N...
Страница 136: ...Appendix B Symbol Sets B 6 PC 8 Code Page 437 Display PC 8 ID Number 10U...
Страница 137: ...Appendix B Symbol Sets B 7 PC 8 Danish Norwegian Display PC 8 DN ID Number 11U...
Страница 138: ...Appendix B Symbol Sets B 8 PC 850 Multilingual Display PC 850 ID Number 12U...
Страница 139: ...Appendix B Symbol Sets B 9 PC 852 Latin 2 Display PC 852 ID Number 17U...
Страница 140: ...Appendix B Symbol Sets B 10 PC 858 Multilingual Display PC 858 ID Number 13U...
Страница 141: ...Appendix B Symbol Sets B 11 PC Turkish Display PC 8 TK ID Number 9T...
Страница 142: ...Appendix B Symbol Sets B 12 Windows 3 1 Latin 1 Display WIN L1 ID Number 19U...
Страница 143: ...Appendix B Symbol Sets B 13 Windows 3 1 Latin 2 Display WIN L2 ID Number 9E...
Страница 144: ...Appendix B Symbol Sets B 14 Windows 3 1 Latin 5 Display WIN L5 ID Number 5T...
Страница 145: ...Appendix B Symbol Sets B 15 Desktop Display DESKTOP ID Number 7J...
Страница 146: ...Appendix B Symbol Sets B 16 PS text Display PS TEXT ID Number 10J...
Страница 147: ...Appendix B Symbol Sets B 17 Ventura International Display VN INTL ID Number 13J...
Страница 148: ...Appendix B Symbol Sets B 18 Ventura US Display VN US ID Number 14J...
Страница 149: ...Appendix B Symbol Sets B 19 Microsoft Publishing Display MS PUBL ID Number 6J...
Страница 150: ...Appendix B Symbol Sets B 20 Math 8 Display MATH 8 ID Number 8M...
Страница 151: ...Appendix B Symbol Sets B 21 PS Math Display PS MATH ID Number 5M...
Страница 152: ...Appendix B Symbol Sets B 22 Ventura Math Display VN MATH ID Number 6M...
Страница 153: ...Appendix B Symbol Sets B 23 PI Font Display PI FONT ID Number 15U...
Страница 154: ...Appendix B Symbol Sets B 24 Legal Display LEGAL ID Number 1U...
Страница 155: ...Appendix B Symbol Sets B 25 ISO United Kingdom Display ISO 4 ID Number 1E...
Страница 156: ...Appendix B Symbol Sets B 26 ISO US ASCII Display ISO 6 ID Number 0U...
Страница 157: ...Appendix B Symbol Sets B 27 ISO Swedish Display ISO 11 ID Number 0S...
Страница 158: ...Appendix B Symbol Sets B 28 ISO Italian Display ISO 15 ID Number 0I...
Страница 159: ...Appendix B Symbol Sets B 29 ISO Spanish Display ISO 17 ID Number 2S...
Страница 160: ...Appendix B Symbol Sets B 30 ISO German Display ISO 21 ID Number 1G...
Страница 161: ...Appendix B Symbol Sets B 31 ISO Norwegian Display ISO 60 ID Number 0D...
Страница 162: ...Appendix B Symbol Sets B 32 ISO French Display ISO 69 ID Number 1F...
Страница 163: ...Appendix B Symbol Sets B 33 Windows 3 0 Latin 1 Display WIN 3 0 ID Number 9U...
Страница 164: ...Appendix B Symbol Sets B 34 Windows 3 0 Baltic Display WIN BALTIC ID Number 10L...
Страница 165: ...Appendix B Symbol Sets B 35 Symbol Display none ID Number 19M Note This Symbol Set is only addressable via a PCL Command...
Страница 167: ...C 1 Appendix C Order Numbers Image Cartridge Druck Kartusche 8709 003 34001 Transfer Roller Unit TRU 8709 003 34002...