![Micromat MM 470A Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/micromat/mm-470a/mm-470a_operators-manual_1787373028.webp)
Section
27
RS232 CONFIGURATION
FORMAT
The format of the data to be transmitted over the serial link is determined by the setting of
the tool switch exactly as for the paper tape option as already described.
TOOL
SWITCH
TYPE
UNITS
REQD ZEROS
0
ASCII
METRIC
Trailing
1
ASCII
METRIC
Leading
2
EIA
METRIC
Trailing
3
EIA
METRIC
Leading
4
ASCII
INCH
Trailing
5
ASCII
INCH
Leading
6
EIA
INCH
Trailing
7
EIA
INCH
Leading
8
not used.
9
EIEIO V42
METRIC
N/A
10 - 15
not use
BAUD RATE
The Baud Rate can be set to 300, 1200, 2400 or 9600 and this is selected by the right hand
digit of the SIL switch.
e.g.
SIL Switch BAUD Rate
01 1200
02 2400
03 300
04 4800
09 9600
MM-TALK SOFTWARE
The left hand digit should be set to "9" when using the interface with a personal computer
running "MM-TALK 2.2" software.
e.g.
TOOL switch to "9"
(Micromat format)
SIL switch to "99"
(MM-TALK, 9600 baud)
5