2. How is blood pressure measured? 

2.1. What is blood pressure, and why does it fluctuate? 

Your level of blood pressure is determined in the circulatory center of the brain and adjusts to 

a variety of situations through feedback from the nervous system. To adjust blood pressure, 

the strength and frequency of the heart (pulse), as well as the width of circulatory blood 

vessels is altered. 

Blood vessel width is affected by way of fine muscles in the blood vessel walls. Your level of 

arterial blood pressure changes periodically during heart activity. During the "blood ejection" 

(Systole), the value is highest (systolic blood pressure value). At the end of the heart’s "rest 

period" (Diastole), pressure is lowest (diastolic blood pressure value). Your blood pressure 

values must lie within certain normal ranges in order to prevent particular diseases. 

2.2. Measurement guidelines 

Blood pressure is very high if your systolic blood pressure is over 160 mmHg and/or your 

diastolic pressure is above 100 mmHg, while at rest. In this case, please consult your 

physician immediately. Long-term values at this level endanger your health due to continual 

damage to the blood vessels in your body. 

If your systolic blood pressure values are between 140 mmHg and 159 mmHg and/or the 

diastolic blood pressure values are between 90 mmHg and 99 mmHg, consult your 

physician. Regular self-checks are necessary. 

If you have blood pressure values that are too low (i.e., systolic values under 105 mmHg 

and/or diastolic values under 60 mmHg), consult your physician. Even with normal blood 

pressure values, a regular self-check with your blood pressure monitor is recommended. 

You can detect possible changes in your values early and react appropriately. 

If you are undergoing medical treatment to control your blood pressure, keep a record of 

values along with time of day and date. Show these values to your physician. 

Never use the results of your measurements to independently alter the medication 

prescribed by your physician. 

Which values are normal? 

The following standards for assessing high blood pressure (in adults) have been established 

by the American Heart Association (AHA) and American College of Cardiology (ACC) in 

2017. 

 

Содержание BP W70 BT

Страница 1: ...BP3KN1 3B 1 IB BP3KN1 3B V4920 EN EN Microlife BP W70 BT BP3KN1 3B User Manual English...

Страница 2: ...ch from the hand This blood pressure monitor IS NOT intended for use with Pregnancy Preeclampsia Children under 12 Neonatal patients WARNING Potentially hazardous situation that if not avoided may res...

Страница 3: ...zardous situation that if not avoided may result in minor moderate injury property damage and or damage to the device This device contains sensitive electronics components Avoid strong electrical or e...

Страница 4: ...against vertically falling water drops when the device is tilted up to 15 Type BF Applied Part Batteries and electronic instruments must be disposed of in accordance with the locally applicable regula...

Страница 5: ...The device has been evaluated to meet general RF exposure requirement The device can be used in portable exposure condition without restriction Trademark Usage Apple the Apple logo iPad and iPhone are...

Страница 6: ...monitor 4 How do I get started 4 1 Inserting the batteries 4 2 Selecting standard or MAM mode 4 3 Selecting Heart Level Indicator 4 4 Setting the date and time 4 5 Setting the user 5 How do I take a...

Страница 7: ...ruction manual carefully to ensure correct use If you have additional questions regarding blood pressure measurements please contact your doctor 1 2 Inflation mode technology Please note that this dev...

Страница 8: ...above 100 mmHg while at rest In this case please consult your physician immediately Long term values at this level endanger your health due to continual damage to the blood vessels in your body If you...

Страница 9: ...n can be ascribed to specific organ malfunctions Please consult your physician for information about the possible origins of your own increased blood pressure values d There are measures you can take...

Страница 10: ...Battery Compartment 6 Cuff 7 Systolic Value 8 Diastolic Value 9 Pulse Rate 10 Date Time 11 Stored Value 12 Traffic Light Indicator 13 Irregular Heartbeat IHB Symbol 14 Cuff Signal Indicator ERR 1 15 C...

Страница 11: ...sure they are correctly connected as shown on the symbols in the compartment If the blood pressure monitor is left unused for long periods remove the batteries from the device 4 2 Selecting standard o...

Страница 12: ...LED is lighted with a heart symbol Conversely 1 or 2 upward arrow s appear when your wrist height is lower to heart level and raise the wrist higher as indication Adjust your wrist to correct height l...

Страница 13: ...that your wrist is free Always ensure that the cuff is positioned correctly as shown in the pictures illustrated on the short instruction card Fit the cuff comfortably but not too tight The cuff will...

Страница 14: ...the ON OFF button e g if you feel uneasy or an unpleasant pressure sensation 5 4 Stopping a measurement If it is necessary to interrupt a blood pressure measurement for any reason e g the patient feel...

Страница 15: ...optimal cuff fit 15 A are not considered in the average value Memory full Pay attention that the maximum memory capacity of 99 memories is not exceeded When the 99 memory is full the oldest value is a...

Страница 16: ...and time must be reset the year number therefore flashes automatically after the batteries are replaced after MAM mode and Heart Level Indicator setting Which batteries and which procedure Use 2 new...

Страница 17: ...minutes until a connection occurs To manually activate the Bluetooth on your monitor press and hold the power button for approximately 4 seconds or until the Bluetooth icon starts blinking If a conne...

Страница 18: ...ate and no result can therefore be displayed Read through the checklist for performing reliable measurements and then repeat the measurement ERR 6 MAM Mode There were too many errors during the measur...

Страница 19: ...ently fails to measure blood pressure values or the values measured are too low too high 1 Check the positioning of the cuff 2 Measure blood pressure again in peace and quiet carefully following the d...

Страница 20: ...p a minimum distance of 3 3 m from such devices when using this device Do not use this device if you think it is damaged or notice anything unusual Never open this device If the device is not going to...

Страница 21: ...improper handling and accidents Professional use not following the operating instructions and alterations made to the monitor or accessory by third parties are also not included in this warranty Some...

Страница 22: ...pulse Cuff pressure display range 0 299 mmHg Resolution 1 mmHg Static accuracy pressure within 3 mmHg Pulse accuracy 5 of the readout value Voltage source 2 x 1 5 V alkaline batteries size AAA Battery...