Connection to Power (cont.)
In accordance with the wiring rules, AS/NZS 3000:2007 and IEC 61000-3-11, the CFEWH is intended for use
in premises having a service current capacity
≥
100 A per phase, supplied from a distribution network having
a nominal voltage of 400/230 VAC. The Live-Neutral electrical supply connections Live, Neutral and Ground
(Earth
) must be
permanently connected to the Terminal Block (14) mounted on the PCBA V6.2 as shown
– noting the correct polarity
Live – L and Neutral – N.
Bring the Live, Neutral supply through the Electric Mains Supply Cable Gland (15) as shown.
The LIVE wire
must be connected to the terminal L
The NEUTRAL wire
must be connected to the terminal N
The EARTH Wire (
gREEN
/
yELLOW
)
must be connected to the terminal
Connection to Power
The unit must be connected to LIVE-NEUTRAL/GROUND (LNG) Electrical Mains Supply.
The appliance
must be connected to the mains supply with fixed wiring. The appropriate mains isolation
switch must be incorporated in-line with the fixed wiring electrical supply.
Installation
Installation
IMPORTANT
This unit is classified as a
Class I
Bare Element Water Heater. The appliance
must be correctly
connected to the mains earth.
In order to prevent a hazardous circumstance occurring due to the inadvertent resetting of the
thermal cut out, the electrical supply to this appliance
must not be supplied through an external
switching device, such as a timer – nor can it be connected to a circuit that is regularly switched
on and off by the electricity supply utility.
IMPORTANT
Live-Neutral/Ground (LNG) connection is polarity dependent.
Incorrect wiring connection will cause FC – Earth Leakage Detection Error.
CFEWH SERIES 1
Isolation Switch
Residual Current
Circuit Breaker
with Overload
Protection - RCBO
N
E
U
T
R
A
L
E
A
R
T
H
L
I
V
E
240VAC
19
20
LED Indicator/Display PCB Plug and Cable
15
Electric
Mains Supply
Cable Gland
8
Printed
Circuit Board
Assembly (PCBA)
Display PCB
21
PCBA Reset
Button
14
Terminal
Block
The earth bracket wire provided must
ALSO be connected to the Terminal Block,
together with the electric mains earth connection.