MicroHeat CFEWH SERIES Скачать руководство пользователя страница 13

CFEWH SERIES 1-10 

  

 

|

    

INSTALLATIoN

 Manual ©2013

    

|

    

MicroHeat Technologies Pty ltd

25

24

Reference

Reference

Maintenance

The unit is designed to provide long and reliable service. Actual life expectancy will vary with water quality and 
use. The unit itself does not require any regular maintenance. 

The CFEWH SERIES 1 has a projected Mean Time Between Failure (MTBF) of 925 hours/17,500 cycles.

However, to ensure consistent water flow, it is recommended to periodically remove scale and dirt that may 
build up in the Inlet Filter (13), the faucet or in the shower head.

IMPORTANT

Other than the Inlet Filter (13), the unit does not contain any user-serviceable parts. In case of 
malfunction, a trained service agent, licensed plumber or electrician is required.

Warranty

WARRANTY FOR MICROHEAT TECHNOLOGIES PTY LTD CONTINUOUS FLOW ELECTRIC HOT WATER 
HEATER (CFEWH) SERIES.

For the MicroHeat Technologies Pty Ltd Continuous Flow Electric Water Heater SERIES (“CFEWH”), MicroHeat will repair or, if necessary, 
at its sole discretion, replace the CFEWH, which falls within the Warranty Periods and Territory specified below, subject to the warranty 
conditions and the warranty exclusions.
Warranty Period within Australia, New Zealand and Papua New Guinea is 3 years from the date of purchase by the consumer as defined 
by the Competition and Consumer Act 2010 (Cth).
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or 
refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the 
goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
It is the responsibility of the consumer to provide proof of purchase within the Territory.

WARRANTy CONDITIONS
1. This warranty is applicable only for CFEWH appliances.

2. The CFEWH must be installed in accordance with the 
MicroHeat CFEWH Installation Instructions, to be supplied with 
the CFEWH water heater, and in accordance with all relevant 
statutory and local requirements of the Country or State in which 
the CFEWH is installed.

3. Where a failed component or CFEWH is replaced under 
warranty, the balance of the original warranty period will remain 
effective. The replaced part or CFEWH does not carry a new 
warranty.

4. Where a failed component or CFEWH is replaced or repaired 
under warranty, MicroHeat will incur all associated costs. 
However, where the CFEWH is installed outside the boundaries 
of a metropolitan area to be defined by MicroHeat or further than 
35 km from an Accredited Service Agent, the cost of transport, 
insurance and travelling costs between the nearest MicroHeat 
Accredited Service Agent’s premises and the installed site shall 
be the owner’s responsibility.

5. Where the CFEWH is installed in a position that does not allow 
safe, ready access, the cost of accessing the site safely, including 
the cost of additional materials handling and/or safety equipment, 
shall be the owner’s responsibility.

6. The warranty only applies to the CFEWH and therefore does 
not cover any plumbing or electrical parts supplied by others and 
not an integral part of the CFEWH, e.g. pressure limiting valve; 
tempering valves; isolation valves; shut off valves; electrical 
switches; electrical cabling; pumps or fuse.

7. The benefits of this warranty are in addition to other rights and 
remedies of the consumer under laws in relation to the goods and 
services to which the warranty relates. 

8. The CFEWH must be sized to supply the hot water in 
accordance with the guidelines in the MicroHeat CFEWH 
literature.

PROCEDURE FOR HONOURINg WARRANTy

1. To initiate a claim for a warranty against defects, the consumer 
shall contact: 

MicroHeat Technologies Pty Ltd 
Unit 6, 38-42 Sabre Drive 
PORT MELBOURNE VIC 3207  
AUSTRALIA 
Phone: (03) 9681 7088

2. The process will then follow the MicroHeat Product Warranty 
Flow Chart to assess whether the product is under warranty.

WARRANTy ExCLUSIONS
Repair and replacement work will be carried out as set out in 
the MicroHeat warranty. However, the following exclusions may 
cause the MicroHeat warranty to become void and may incur a 
service charge and/or cost of parts:

1. Accidental damage to the CFEWH or any component, including: 
Acts of God; failure due to misuse, abuse, fire or flood damage; 
incorrect installation; damage as the result of transportation, 
removal or storage; attempts to repair the CFEWH other than by 
a MicroHeat Accredited Service Agent, the MicroHeat Service 
Department or a repairer not approved by MicroHeat.

2. Where it is found there is nothing wrong with the CFEWH 
water heater; where the complaint is related to circumstances 
where there is no flow of hot water due to faulty plumbing; 
where water leaks are related to plumbing and not the CFEWH 
or CFEWH components; where there is a failure of electricity or 
water supplies; where the supply of electricity or water does not 
comply with relevant standards, codes or acts, MicroHeat may 
then charge the consumer a nominal service charge if inspection 
reveals no fault with the CFEWH unit or its installation.

3. Where the CFEWH or CFEWH component has failed directly 
or indirectly as a result of excessive water pressure in excess 
of 10bar; incorrect pressure limiting valves; incorrect tempering 
valve settings; temperature input in excess of 85ºC and/or 
excessive thermal input; blocked outlet; corrosive atmosphere; 
foreign matter in the water supply; or ice formation in the pipe 
work to or from the CFEWH water heater.

4. Where the CFEWH is located in a position that does not 
comply with the MicroHeat CFEWH Installation Instructions 
or relevant statutory requirements, causing the need for major 
dismantling or removal of cupboards, doors or walls, or use of 
special equipment to bring the CFEWH to a serviceable position.

5. Repair and/or replacement of the CFEWH due to the effects 
of either corrosive water or water with a high chloride or low pH 
level caused by unnatural circumstances or when the CFEWH has 
been connected to a water supply with water conductivity levels 
that are outside the range of water conductivity outlined in the 
Installation Instruction Manual.

Subject to any rights you have under Australian Consumer Law 
or other statutory provisions to the contrary, this warranty 
excludes any and all claims for damage to furniture, carpets, 
walls, foundations or any other consequential loss either directly 
or indirectly due to leakage from the water heater, or due to 
leakage from fittings and/or pipe work of metal, plastic or other 
materials caused by water temperature, workmanship or other 
modes of failure.

Содержание CFEWH SERIES

Страница 1: ...tinuous Flow Electric Water Heater CFEWH SERIES 1 10 INSTALLATION MANUAL Single Phase CFEWH Series 1 10 Premium Model Extension pipe cover sold separately Hot water just got smarter www microheat com...

Страница 2: ...ludes a display showing Output Water Temperature and Flow Rate Standard CFEWH CFEWH SERIES 1 10S The Exterior Cover has only a RED GREEN indicator LED This Installation Manual covers Series 1 10 Premi...

Страница 3: ...how the efficiencies and savings are achieved all you need to do is follow our simple explanation The secret of optimised energy The unit intelligently optimises the amount of energy it needs to heat...

Страница 4: ...to comply with the installation and operating instructions outlined in this manual or through improper use Improper use includes the use of this appliance to heat any liquid other than potable water w...

Страница 5: ...inate RED See page 22 in the Reference Section for the List of Error Descriptions If the LED illuminates RED constantly the unit has entered an irresolvable error condition and requires technical inte...

Страница 6: ...tallation Installation WARNING Body must NOT be drilled note NO DRILL symbols located on Flange Mounting Screw Hole Locations 6 7in 170mm 11 2in 285mm 5 3in 135mm 0 2in 4 4mm 6 6in 168 9mm 8 2in 207 6...

Страница 7: ...Mounting to the Wall cont Installation Installation 15 Electric Mains Supply Cable Gland Fitting IMPORTANT When mounting the unit to a wall it is very important that no holes are drilled within the ar...

Страница 8: ...a 10 bar 150 PSI The installation of a pressure limiting valve a mandatory requirement ensures that excess water pressure applied as result of water hammer and or other circumstances does not stress t...

Страница 9: ...ing The appropriate mains isolation switch must be incorporated in line with the fixed wiring electrical supply Installation Installation IMPORTANT This unit is classified as a Class I Bare Element Wa...

Страница 10: ...power kick is not required at start up STEP 1 Flush Flushing is required to clear the unit of plumbing debris that may have collected in the piping during installation Remove the Inlet Filter 13 whil...

Страница 11: ...stalled inside a dwelling or construction and should not be exposed to splashing water rain or any circumstance that will allow water to enter the outside cover Ambient Temperature The unit is intende...

Страница 12: ...perature too low A4 Blocking Resolving Flashing RED Operating temperature too high A5 Blocking Resolving Flashing RED Outlet water temperature 5 C above set point A6 Blocking Resolving Flashing RED In...

Страница 13: ...ting valve tempering valves isolation valves shut off valves electrical switches electrical cabling pumps or fuse 7 The benefits of this warranty are in addition to other rights and remedies of the co...

Страница 14: ...NZS 60335 2 35 A 13670EA E1109 0066 1 C Tick N29465 For technical support during or after installation phone 03 9681 7088 MicroHeat Technologies Pty Ltd Unit 6 38 42 Sabre Drive PORT MELBOURNE VIC 32...

Страница 15: ...ISSUE 2 April 2013 DISTRIBUTED BY Hot water just got smarter...

Отзывы: