© Microhard Systems Inc.
Confidential
63
4.0 Register/Command Reference
S108 Output Power
20 (100)
21 (125)
22 (160)
23 (200)
24 (250)
25 (320)
This setting establishes the transmit power level which will be
presented to the antenna connector at the rear of the modem.
Unless required S108 should be set not for maximum, but rather for
the minimum value required to maintain an adequate system fade
margin.
Values (dBm (mw))
26 (400)
27 (500)
28 (630)
29 (800)
30 (1W)
FCC regulations allow
for up to 36dBi effective
isotropic radiated power
(EIRP). The sum (in
dBm) of the transmitted
power, the cabling loss,
and the antenna gain
cannot exceed 36dBi.
1
Values (1-65535 or 1-255)
S105 Unit Address
The unit address is, and must be, a unique identifier of each modem in
a network. The address value is 16-bits in length.
The Master has by default, and must retain, a unit address of 1; 65535
is the broadcast address. Refer to the specific modem type for more
information in regards to unit addressing.
Values (up to 16 char)
S107 Static Mask
default
(the word itself)
This mask
is applied to the transmitted data, and removed from the
received data. It is an added form of security for a network.
For NB modems it is used by Pacific Crest protocol for security
purposes. Default: Empty String
Change S107 to
something unique for your
network.