© Microhard Systems Inc.
139
4.0 Configuration
Image 4-11-5: Apps > Local Monitor
4.11.3 Apps > Local Monitor
The Local Device Monitor allows the BulletPlus to monitor a local device connected locally to the Ethernet
port or to the locally attached network. If the BulletPlus cannot detect the specified IP or a DHCP assigned
IP, the unit will restart the DHCP service, and eventually restart the modem to attempt to recover the
connection.
IP Mode
Select the IP mode. By selecting a fixed IP address the service will monitor
the connection to that specific IP. If auto detect is selected, the BulletPlus
will detect and monitor DHCP assigned IP address.
Status
Enable or disable the local device monitoring service.
Disable /
Enable
Values (selection)
Fixed local IP
Auto Detected IP
Values (selection)
Local IP Setting
This field is only shown if Fixed Local IP is selected for the IP Mode. Enter
the static IP to be monitored in this field.
0.0.0.0
Values (IP)
Status Timeout
The status timeout is the maximum time the BulletPlus will wait to detect
the monitored device. At this time the BulletPlus will restart the DHCP
service. (5-65535 seconds)
10
Values (seconds)
Waiting DHCP Timeout
This field defines the amount of time the BulletPlus will wait to detect the
monitored device before it will reboot the modem. (30-65535 seconds)
60
Values (seconds)