multiplier is indicated by flashing x100 indicator. Bottom power reading scale is shortened to half. Final value is 
given by multiplying  indicated value on the current scale by RANGE multiplier. 

Current scale on TOP bar is indicated by one of SCALE indicators [3], and current RANGE is indicated by one of 
RANGE indicators [5]. BOTTOM bar scale is indicated by its own SCALE [4] and RANGE indicator [5]. While 
scale indicators for top and bottom bar are separate, range indicators are shared and differentiated by color. 
TOP bar uses GREEN range indicator, BOTTOM bar RED indicator. When RANGE multiplier for both bars is the 
same (rare but may happen), RANGE indicator is  YELLOW. 

Any selected power type for top and/or bottom bar graph is always shown in W [Watt] units. When bar shows 

POWER, 

both bars can have independently defined four (4) power ranges, and for each power range one of 

three (3) available colors can be assigned, for each band, each screen separately. These ranges and not related 
to scale ranges described above, they may start and end anywhere from 0W up to maximal power. Advantage of 
colored ranges is readability. When you set for example 50-100W range to be shown in red color, power from 
50-100W will always be shown in red color, regardless of scale range (it doesn't matter if you are in 100W scale 
or 2000W scale). In this way you can make some nicely visible important power areas like optimal driving power 
for amplifier, maximal power to certain antenna etc ...

When bottom bar [2] shows 

SWR

 instead of reflected power, it is indicated by YELLOW SWR scale indicator [4]. 

SWR has its own, specialized scale divided to four (4) linear sub-scales in order to achieve fast, simple and 
precise readout. SWR from 1.0 to 3.0 -  the most important section - has linear division of 0.05 per bar segment. 
It takes 80% of the bar length. SWR from 3.0 to 4.0 has division of 0.2 per segment, from 4.0 to 7.0 division 1 per 
segment, while SWR 7 segment is lit when SWR is up to 10. Last but one shows SWR from 10 to 15, last one 
everything higher than 15. Same as for the power, also for SWR four (4) custom color ranges can be defined in 
the BOTTOM BAR MENU, on per band basis, settings follow the same segmented scale, but this time in a same 
division and ranges as are defined SWR sub-scales. 

When bars are configured to show parts of 

Complex Impedance

, the two scales printed in between the two LED 

bars are used. Scale above the central line applies to the top bar graph and shows Resistance R or Absolute 
value of Impedance |Z| in 0 - 100Ω range. Scale below the central line applies to the bottom bar graph and 
shows Reactance X or Phase angle Φ in -100 to +100Ω or -100 to +100

º

 range.

Bar graphs can operate in MANUAL or AUTO RANGE mode. 

ROTARY KNOB

 [14] is used to select the mode 

and to select range in MANUAL mode. When rotated in CW direction it changes range from the lowest (least 
sensitive) to the highest respectively. When rotated in CCW direction, very last CCW position is AUTO RANGE. 
In AUTO RANGE mode meter switches range upward immediately but down-ranges with timeout. BARS 
DOWNRANGING timeout is adjustable in SYSTEM MENU | MISCELLANEOUS if you don't like the default 
value.

When rotary knob is 

depressed and rotated

, it changes ranges for bottom bar in a same manner as for top bar.

In MANUAL mode it is possible to overload current range. Overloaded range  is indicated by fast flashing SCALE 
indicator [3]. Each range allows 2% overload without overload indication. Since bar graphs are software driven, 
there is no damage even if they are hugely overloaded for a long time, don't worry if it happens.

Last but one CCW range position of the rotary knob is percentage (%) range. When enabled, it is indicated by % 
RANGE indicator [5]. This range is useful for instant checking if everything is as should be, because 100% power 
level is always full deflection on linear scale without any range switching. 100% power levels can be precisely set 
on per sensor, per band basis in SENSOR MENU according to your specific requirements or available power. 
100% power level value is also used in TUNE SCREEN, optimized SCREEN for tuning manual Power Amplifiers 
or Antenna Tuners.

10

Содержание SMORF

Страница 1: ...microHAM 2015 All rights reserved SM RF RF VECTOR SIGNAL METER microHAM fax 421 2 4594 5100 e mail support microham com homepage www microham com Version 1 4 8 April 2016 1...

Страница 2: ...EN Screens Menu 18 7 SINGLE SENSOR SCREEN TEMPLATES 20 STANDARD Screen 20 LARGE Screen 21 PSK Screen 22 TUNE Screen 23 TECHNICAL Screen 24 OSCILLOSCOPE Screen 26 SPECTRUM Screen 29 AUTO Mode 31 8 DUAL...

Страница 3: ...WR Alarm 60 LOW POWER Alarm 61 HIGH POWER Alarm 62 PSK IMD Alarm 62 ARCING Alarm 63 13 DATA STRUCTURE DIAGRAM 64 14 SENSORS 65 15 REMOTE CONTROL 66 HTTP Server 66 VNC Server 68 Remote Control Applicat...

Страница 4: ...temperature Very wide viewing angle sunlight readable high contrast graphics OLED display Multiple user configurable display screens for powers impedance waveform spectrum PSK SO2R User configurable a...

Страница 5: ...ctional couplers All sensors have internal micro controller and EEPROM memory for calibration data storage Micro controller measures internal temperature of the coupler and provides these data on requ...

Страница 6: ...er switches to the AUTO mode and automatically focuses to the first sensor passing sensing nonzero power when pushed and held together with SENSOR 2 for one second meter switches to the DUAL mode and...

Страница 7: ...rves as INPUT 4 in 4 INPUT mode 5 PTT INHIBIT IN1 configurable input coupled to SENSOR 1 6 PTT INHIBIT OUT1 configurable output coupled to SENSOR 1 7 PTT INHIBIT IN2 configurable input coupled to SENS...

Страница 8: ...ur interface or you have interface without iLINK port please refer to ALARM SETTINGS chapter for more details This connection is not necessary for SM RF functionality but when used SM RF can protect y...

Страница 9: ...her for one second meter switches to DUAL mode When meter switches to the DUAL mode it provides measurement results of both sensors at the same time Please note AUTO mode and DUAL mode availability de...

Страница 10: ...up to 10 Last but one shows SWR from 10 to 15 last one everything higher than 15 Same as for the power also for SWR four 4 custom color ranges can be defined in the BOTTOM BAR MENU on per band basis...

Страница 11: ...dure which needs to know the frequency of incoming signal therefore is important to see it on all the time If measured signal is very low in power it may happen that the signal is too weak to measure...

Страница 12: ...ANT subscripts REF When you look at most of SCREENs you certainly wonder what these TX and ANT subscripted suffixes means They present another unique feature of the SM RF called two point measurement...

Страница 13: ...ar graph you have to enter EDIT mode and select field parameter right next to T BAR or B BAR icon in top STATUS bar depends on if you want to change top or bottom bar function When parameter is select...

Страница 14: ...mplex impedance R green jX red at the ANT Antenna feed point 13 Z TX Z Dual display of polar coordinates complex impedance Z green red at the TX Sensor feed point 14 Z ANT Z Dual display of polar coor...

Страница 15: ...be lit on its position Occurrence of higher peak value during the hold will restart this time Range 0 20s Step 100ms 7 P H DECAY Sets decay time for peak hold segment Range 0 20s Step 100ms 8 EDIT POW...

Страница 16: ...ed output signal works in continuous or single shot mode with adjustable time duration Transformer isolated output is compatible with both balanced and unbalanced microphone inputs output level is adj...

Страница 17: ...ep Range 1 V 130mVp p Step 1 10 MONITOR Enables and sets monitoring level of signal generator output through internal speaker Please note if you do require extreme output signal purity keep it OFF CON...

Страница 18: ...power overshoots These overshoots can be caused by poor power supply regulation and ALC Virtually every transceiver generates overshoots at the beginning of transmission until ALC loop stabilizes hun...

Страница 19: ...d two advanced alarms PSK IMD alarm and ARCING alarm While Alarms settings are individual for each sensor their settings apply to all sensor s SCREENs SCREEN MENU allows further setting individually e...

Страница 20: ...xample 0dBm 1mW 50dBm 100W 53dBm 200W 60dBm 1kW 0dBW 1W 20dBW 100W 23dBW 200W 30dBW 1kW TYPE After the UNIT field TYPE is displayed as subscript SM RF supports four power types PK Peak Envelope Power...

Страница 21: ...jX complex impedance at the ANT Antenna feed point IMPANT Polar coordinates Z complex impedance at the ANT Antenna feed point LARGE SCREEN Large screen is a screen providing two 2 user configurable m...

Страница 22: ...mental component Level of these harmonics has main impact to the output signal purity They are shown dimmed when their level is too low to be certain for IMD quantification below dynamic range All mea...

Страница 23: ...T Standing Wave Ratio at the ANT Antenna feed point RLTX Return Loss dB at the TX Sensor feed point RLANT Return Loss dB at the ANT Antenna feed point 3 PERCENTAGE Shows ratio of current power to 100...

Страница 24: ...ontesting Now we are going to describe screens which you normally don t use every day but are extremely helpful for TX signal chain checking troubleshooting experimenting on antennas and matching netw...

Страница 25: ...nates complex reflection coefficient for both TX and ANT points Re j Im Real and Imaginary part of the reflection coefficient Polar coordinates complex reflection coefficient for both TX and ANT point...

Страница 26: ...it CONTROLS 1 MODE Sets oscilloscope operating mode ROLL Rolling mode In Rolling mode screen scrolls from the right to left while new data appears on the right side Speed of scrolling depends on hori...

Страница 27: ...n captured waveform They can work in two modes Tracking and Free mode In Tacking mode indicated by CT icon Y position of the cursor is stuck to the waveform while X position can be adjusted In Free mo...

Страница 28: ...fixed rate of 125 thousands samples per second For easier to use decade ranges low ranges or advanced acquisitions scope uses real time decimation and interpolation operations Therefore minimal and ma...

Страница 29: ...y presented in in table on the right side of display Bottom line of the table with sign shows difference between CURSOR 1 and CURSOR 2 for both amplitude and frequency Cursors have slightly different...

Страница 30: ...microHAM 2015 All rights reserved intentionally left blank 30...

Страница 31: ...transceivers where meter automatically switches between sensors according to operating band HF vs VHF or UHF or for SO2R contesting setups where only one transceiver transmits at a time AUTO mode is n...

Страница 32: ...elope forward power minus reflected power delivered power at the TX feed point FWDANT REF Peak envelope forward power minus reflected power delivered power at the ANT feed point FWDTX Forward power at...

Страница 33: ...ided In the rectangle box Gain and Phase between Sensor 2 and Sensor 1 respectively are shown Available measurements 1 FORWARD POWER FWDTX REF Peak envelope forward power minus reflected power deliver...

Страница 34: ...microHAM 2015 All rights reserved intentionally left blank 34...

Страница 35: ...n at four 4 simultaneously updated horizontal bar graphs as well as their numerical values in dBm right next to the bar graphs Bar graphs have linear 50dB range maximal value can be set manually from...

Страница 36: ...evel is below the frequency lock level rise amplitude of each signal separately until it locks Phase measurement is principally not possible different frequencies If you are going to measure three or...

Страница 37: ...il MENU disappears by brief pushes of the MENU button Even thought MENU always starts at root MAIN MENU screen last path through the menu branches is remembered by simple pushing MENU button you get w...

Страница 38: ...MK2R it is necessary to set radio assignment it defines which SM RF belongs to the RADIO 1 and which belongs to the RADIO 2 1 METER MODE Sets meter mode of the SM RF 2 RADIO ID ASSIGNMENT Sets radio...

Страница 39: ...N3 IN4 In series setup this sensor should be placed after the tested device towards load or antenna If you are connecting two SM RF boxes to iLINK bus of MK2R it is necessary to set radio assignment i...

Страница 40: ...have two sensors and often changing RF setup due to various experiments it doesn t force you to change METER MODE on every sensor s change 11 SCREEN NAME Sets how long the SCREEN name will be shown o...

Страница 41: ...GRAPHs Please note 0 intentionally does not turn light off but sets them to some minimal usable level 3 AUTO MIN Sets minimal intensity of the LED BAR GRAPHs 4 AUTO MAX Sets maximal intensity of the...

Страница 42: ...ction usually your local Router or ISP 4 MANUAL Allows to set the IP ADDRESS NET MASK GATEWAY and DNS ADDRESS manually When you consequently re enable LAN parameters are copied to appropriate position...

Страница 43: ...g moving parameters Parameters can be individually enabled or disabled Available parameters are UTC time DATE LOCAL TIME and CALLSIGN Callsign can be edited on screen by default it is set to microHAM...

Страница 44: ...microHAM 2015 All rights reserved SYSTEM MENU AUX PORT intentionally left blank 44...

Страница 45: ...WAIT RESPONSE RTC is waiting for response from the NTP server This happens when the NTP server is busy or not responding WAIT FOR DNS RTC is waiting for response from the DNS server This happens when...

Страница 46: ...a are exported to the computer together with content of all three backup slots When you restore config data from the computer back to the SM RF SM RF updates also sensor s data As was described SM RF...

Страница 47: ...S ORDER This menu allows to set if particular screen will be shown in sequence of screens for the selected sensor and allows to customize the NAME of the screen Menu provides table each row is assigne...

Страница 48: ...selected data will be copied If ALL is selected data will be copied to all screens of selected sensor EXCEPT disabled screens NO in SENSOR x SCREENS ORDER menu 3 SENSOR Sets destination sensor where s...

Страница 49: ...a table where attenuation and phase difference of the cables connecting the Sensor to the SM RF is defined To understand why this table is important to overall accuracy of the system it is necessary t...

Страница 50: ...nts to get exact value of the attenuation and the phase for current operating frequency in real time By default the Sensor Cables Table is pre set using typical values of the attenuations of provided...

Страница 51: ...each end If you prefer to make them yourself make sure to cut them for exactly same physical length and solder or crimp connectors precisely If you need even longer cables use thick 7 12mm cable doubl...

Страница 52: ...or radio common situation on VHF or UHF bands In this case whenever it is possible calibrate cables also on adjacent bands As was mentioned SM RF calculates attenuation for other than calibration freq...

Страница 53: ...cable is identified by its unique ID number There are more than thirty 30 built in precise models of common coaxial cables types to choose from There is one special cable called Lossless 50 which is...

Страница 54: ...r is generated from the opposite side of the coupler it has impact to level of reflected sample On U I couplers where U and I samples are equal in amplitude under matched conditions it causes false tr...

Страница 55: ...SOR s 2 data to SENSOR 1 CONTROLS 1 DATA Sets data going to be copied HiPWR ALARMS copies High Power Alarms LoPWR ALARMS copies Low Power Alarms SWR ALARMS copies SWR Alarms PSK ALARMS copies PSK Alar...

Страница 56: ...alarm types later Each alarm type can trip three different user adjustable levels of importance These levels are WARNING ALARM and FAULT WARNING represents the lowest level of importance ALARM middle...

Страница 57: ...resets alarm Alarm can be reset also remotely from the remote control application running on the computer It is recommended to use MANUAL reset for FAULT level of alarms which makes you aware of crit...

Страница 58: ...sistors and radio is consequently connected to misbehaving load If you like your equipment never do this Proper sequence when SWR gets high is to force radio to stop generating power as quickly as pos...

Страница 59: ...state by MOX button in FSK RTTY mode CONTROLS 1 SOUND Selects sound for audible alarm alert 2 CYCLE Sets number of sound repetitions 3 LEVEL Sets volume of the sound 4 TRY Allows to check the sound 5...

Страница 60: ...breaks power generated by the radio TX BREAK YES If output power will be higher than 180W SM RF will generate ALARM and FAULT level alarms with the same actions and reset conditions as above but at d...

Страница 61: ...W W PWR to 1100W A PWR to 900W and F PWR to 200W While power will be larger than 1150W everything will be OK and no LOW POWER alarms will be generated However if power drops and be in between 1100 115...

Страница 62: ...be lower than 1220W everything will be OK and no HIGH POWER alarms will be generated However if power rises and be in between 1220 1250W SM RF will generate WARNING indicating that the amplifier is b...

Страница 63: ...nother special SM RF s unique advanced type of alarm Of course detection of real arcing with just sensor is not technically possible but it is possible to detect side effect of the arcing and it is sh...

Страница 64: ...microHAM 2015 All rights reserved 13 DATA STRUCTURE DIAGRAM 64...

Страница 65: ...peratures at a plane of LOAD connector to the plane of SMA sample connectors These data are stored in this EEPROM memory When sensor is attached to the SM RF and is powered up for the first time SM RF...

Страница 66: ...0MBit s networks On LAN SM RF uses TCP and UDP protocols and provides two internal servers for standard remote access HTTP SERVER HTTP server is designed for basic maintenance of the SM RF from Intern...

Страница 67: ...y irrecoverably corrupt data and backups in the SM RF memory Proper procedure is 1 Backup config 2 Update firmware 3 Restart SM RF 4 Restore config 5 Restart SM RF Config Backup Restore function at Fi...

Страница 68: ...able for Windows OS X Linux Raspberry Pi Android and iOS systems To access SM RF from the viewer first make sure that the SM RF is connected to your local network and has assigned IP address Go to SYS...

Страница 69: ...tive session can be assigned for auto connect when Connect after start up box is checked 3 Options Switch to COMPACT mode after connected Remote Control starts in COMPACT mode Preserve window layout r...

Страница 70: ...for the TOP BAR GRAPH 11 BOTTOM BAR GRAPH RANGE Sets range for the BOTTOM BAR GRAPH 12 CONNECT DISCONNECT Connects or disconnects to active session 13 LAT BW Shows current latency and occupied bandwi...

Страница 71: ...low Dot or Bar mode Point of measurement Sensor point and antenna point for all measurements Power ranges 5 range multipliers x0 1 x1 x10 x100 1000 and 3 linear scales 10 20 50 for total 14 full scale...

Страница 72: ...20 up to 500MHz Relative Power accuracy 4 CHF 3 0 1 1W 3 1W 600W 2 600 3000W 2 5 from 1 8MHz 54MHz CVHF 2 0 3 3W 3 3W 2000W 2 at 70MHz 0 2 2W 3 2W 2000W 2 at 145MHz 0 1 1W 3 1W 400W 2 400 2000W 2 5 at...

Страница 73: ...6 Operating temperature range 20 to 60 C sensor Dimensions W 88mm D 150mm H 47 79mm body incl connectors Weight 460g CVHF 2 Operating frequency range 70MHz to 500MHz directional coupler Characteristic...

Страница 74: ...0g CHF 6 Operating frequency range 1 8MHz to 54MHz U I type sensor Maximal Power 6000W ICAS 4000W CCS RF ports connectors Power side 2x 7 16DIN female meter side 2x SMA female Input Return Loss TBD In...

Страница 75: ...ay or the warranty is voided The warranty does not cover damage caused by improper or abnormal use failure to follow instructions improper installation lightning or excessive power The product will be...

Страница 76: ...ence received including interference that may cause undesired operation European Union Declaration of Conformity microHAM s r o declares that the product Product Name RF VECTOR SIGNAL METER Conforms t...

Отзывы: