micro
HAM ©
2015
All rights reserved
SYSTEM MENU – MISCELLANEOUS SETTINGS
In this menu it is possible to check the version of the firmware, serial numbers of internal boards and set various
global and user interface settings. Settings are applied to both SENSORs and all SCREENs.
1.
FIRMWARE VERSION
Shows version of the firmware.
2.
SERIAL NR MAIN
Shows serial number of the Main Board.
3.
SERIAL NR RF
Shows serial number of the RF Board.
4.
CALIBRATION
Shows date of the SMΩRF calibration.
5.
BUTTONS BEEP
Sets level of audible feedback to button
presses. 0% disables button's sound.
6.
UNITS
Sets units provided by SMΩRF for
temperature and length. It can be set to
METRIC or IMPERIAL system.
7.
SERIAL PORT
Sets RS232 Serial Port speed. Range
1200 - 115200Bd.
8.
HELP LANGUAGE
Sets language of built-in HELP system.
9.
STARTUP SPLASH
Sets how long startup screen will be held on the display.
10.
STRICT METER MODE
Limits METER MODE.
When set to NO, SCREENs, AUTO mode and DUAL mode are not limited to METER MODE.
NO is not recommended setting, however, if you have two sensors and often changing RF setup due to
various experiments, it doesn't force you to change METER MODE on every sensor's change.
11.
SCREEN NAME
Sets how long the SCREEN name will be shown on display when SCREEN is changed.
12.
BAR RANGE STATUS
Sets how long the BAR GRAPH range notification will be shown on display when RANGE is changed.
13.
BAR RANGE MEMORY
Sets if current BAR GRAPH range is remembered for each SCREEN.
YES settings makes BAR GRAPH ranges independent for each SCREEN.
NO uses current BAR GRAPH range on all SCREENs of the sensor.
14.
BARS DOWNRANGING
When bar graphs are in AUTO mode, sets timeout for switching to more sensitive ranges.
15.
TUNE SENSITIVITY
Sets sensitivity to the carrier stability (variation in amplitude) for automatic jump to the TUNE screen.
Larger the number, more stable carrier is required.
16.
TUNE TRIG TIME
Sets how long the stable carrier (stability requirement is defined in the TUNE SENSITIVITY) must last to
accept carrier as a command for automatic jump to the TUNE screen.
17.
TUNE HOLDOFF
Sets how long the TUNE screen will be held on the display when tuning carrier signal disappears. After
timeout screen returns to the original screen from where it jumped to the TUNE screen.
40
Содержание SMORF
Страница 30: ...microHAM 2015 All rights reserved intentionally left blank 30...
Страница 34: ...microHAM 2015 All rights reserved intentionally left blank 34...
Страница 44: ...microHAM 2015 All rights reserved SYSTEM MENU AUX PORT intentionally left blank 44...
Страница 64: ...microHAM 2015 All rights reserved 13 DATA STRUCTURE DIAGRAM 64...