OPERATOR SETTABLE ALARMS
OPERATOR SETTABLE ALARMS
OPERATOR SETTABLE ALARMS
OPERATOR SETTABLE ALARMS
CONTINUED
WORK AREA SELECTION MODE
WORK AREA SELECTION MODE
WORK AREA SELECTION MODE
WORK AREA SELECTION MODE
•
Press the operator alarm push button (item
24) two times to access the Work Area
alarm screen.
SETTING POINTS 1 AND 2
•
Move the boom, attachment, load, rigging
etc. to the desired
LEFT SET POINT.
•
Press the push button (item 25) pointing to
Left Point. The information screen (item 1)
will read
LEFT POINT SET
.
Both Left and Right Points must be set for the
system to operate correctly. The red warning
light (item 5) will flash and the audible alarm will
sound whenever only one of the left/right swing
limits is set.
•
Move the boom, attachment, load, rigging
etc. to the desired
RIGHT SET POINT.
•
Press the push button (item 27) pointing to
Right Point. The information screen (item 1)
will read
RIGHT POINT SET.
The red warning light (item 5) will flash and the
audible alarm will sound whenever the boom tip
penetrates the exclusion zone.
Pressing the
LEFT POINT
and
RIGHT POINT
push buttons (items 25 & 27) again will cancel
the alarm and the information screen (item 1)
will read
LEFT POINT OFF RIGHT POINT OFF
LEFT SWI NG OFF RIGHT SWING OFF
LEFT POI NT SET RIGHT POINT SET
TES T
M AX
SE T
6
2 3 ,5 0 0
i2 ,3 0 0
4 4 .8
6 2 .7
2 6 .4
24
25
5
27