RCI 510 RATED CAPACITY INDICATOR OPERATOR'S MANUAL
TEL:(714) 259-9702 FAX:(714) 259-7626
29 of 35
OPERAT
OPERAT
OPERAT
OPERATOR SETTABLE ALARMS
OR SETTABLE ALARMS
OR SETTABLE ALARMS
OR SETTABLE ALARMS
CONTINUED
SETTING LEFT SWING A
SETTING LEFT SWING A
SETTING LEFT SWING A
SETTING LEFT SWING ALARM
LARM
LARM
LARM
•
Swing the boom to the desired Left Swing
Limit, e.g. 325°.
Press the operator alarm push button (item
24) 2 times to access the swing alarm
screen.
•
Press the push button (item 28) pointing to
Left Swing. The information screen (item 1)
will read
LEFT SWING 325°
.
Both Left and Right Swing Alarms must be set
for the system to operate correctly. The red
warning light (item 5) will flash and the audible
alarm will sound whenever only one of the
left/right swing limits is set.
SETTING RIGHT SWING
SETTING RIGHT SWING
SETTING RIGHT SWING
SETTING RIGHT SWING ALARM
ALARM
ALARM
ALARM
•
Move the boom to the desired Right Swing
Limit, e.g. 35°.
•
Press the Right Swing push button (item
29). The information screen (item 1) will
read
RIGHT SWING 35°.
The red warning light (item 5) will flash and the
audible alarm will sound whenever the boom
swings past the preset limits.
Pressing the LEFT SWING and RIGHT SWING
push buttons again will cancel the alarm and the
information screen (item 1) will read:
LEFT SWING OFF RIGHT SWING OFF.
LEFT SWING 325 RIGHT SWING 35
LEFT POINT OFF RIGHT POINT OFF