RCI 510 RATED CAPACITY INDICATOR OPERATOR'S MANUAL
TEL:(714) 259-9702 FAX:(714) 259-7626
26 of 35
OPERATOR SETTABLE ALARMS
OPERATOR SETTABLE ALARMS
OPERATOR SETTABLE ALARMS
OPERATOR SETTABLE ALARMS
CONTINUED
CONTINUED
CONTINUED
CONTINUED
SETTIN
SETTIN
SETTIN
SETTING MAXIMUM BOOM LENGT
G MAXIMUM BOOM LENGT
G MAXIMUM BOOM LENGT
G MAXIMUM BOOM LENGTH ALARM
H ALARM
H ALARM
H ALARM
•
Move the boom to the desired maximum
length, in this example 58 ft.
•
Press the operator alarm push button (item
24) to access the operator alarm screen.
•
Press the push button (item 25) pointing to
Max Length. In this example the display will
read
MAX LENGTH 58 FT
.
•
The red warning light (item 5) will flash and
the audible alarm will sound whenever the
boom length exceeds 58 ft.
Pressing the MAX LENGTH push button again
will cancel the alarm and the display will read
MAX LENGTH OFF.
SETTING MAXIMUM TIP
SETTING MAXIMUM TIP
SETTING MAXIMUM TIP
SETTING MAXIMUM TIP HEIGHT ALARM
HEIGHT ALARM
HEIGHT ALARM
HEIGHT ALARM
•
Move the boom to the desired maximum
height, in this example 78 ft.
•
Press the operator alarm push button (item
24) to access the operator alarm screen.
•
Press the push button (item 27) pointing to
Max Height. In this example the display will
read
MAX HEIGHT 78 FT
.
•
The red warning light (item 5) will flash and
the audible alarm will sound whenever the
boom tip height exceeds 78 ft.
Pressing the MAX HEIGHT push button again
will cancel the alarm and the display will read
MAX HEIGHT OFF.
MIN ANGLE OFF
MAX LENGTH 58.0 MAX HEIGHT 78.0
TEST
MAX
SET
MAX ANGLE OFF
6
23,500
i2,300
44.8
62.7
26.4
24
25
5
27