Series 3500
Installation
1. Wire in the power adapter. To do this, simply place one wire from the adapter under one of the
screwdown terminals and the other wire under the other screwdown terminal (refer to the wiring
diagram decal on the back of the display.) Then, plug in the power adapter and check the display
for proper operation.
2. Microframe displays can be hung on the wall similar to a picture frame. There is a keyhole in the
back of the display for this purpose.
Operation
If you purchased this Display for use with a MultiPage Transmitter, you should be able to simply plug in
the display and then enter and delete numbers as specified in the “MultiPage Operation” section. If
you are using this display with another transmitter, please read "Using the Display with Alternate
Transmitters” that is located on the following page.
Configuration
The display configurations fall into two basic categories. The first is "Display Communication Settings,"
and the second is "Display Behavior Settings." However, under normal circumstances, you will not
need to change the display configuration.
•
Display Communications Settings
The display comes from the factory ready to communicate with a MultiPage Transmitter (Base
ID 0500000, Baud Rate 1200). The display will intelligently communicate with other settings
by doing the following:
Press the button on the back of the display one time. The display will show vertical bars.
Next, page Pager number 1 with a beep type of 2 and message 7337. The display should
change to horizontal bars to signify that it has learned the transmitter identity (Base ID and
Baud Rate). If the display does not receive a valid transmission within 90 seconds, it will show
"EE".
•
Display Behavior Settings
The display's behavior can be changed by sending special codes to Pager 9999. All codes are
indicated by the form XX_XX or XX_XXXX where "_" is a space. Use the [SETUP] key to
insert a space in a message. There are five settings that can be changed using the 9999
command as seen below.
•
Mode Settings - The display has two possible Modes:
Mode 1 displays the messages sent to a specific vibrating pager.
Mode 1) To program the display to show all messages sent to Pager 300. Send a
page to Pager 9999 with the message “00_0300.”
NOTE: You must use the [SETUP] key to insert the space in the message between 00
and the Pager number. The Display will now show all messages sent to Pager 300.
Mode 2 displays all pager numbers paged by the transmitter.
Mode 2) To program the display to show all pages sent by the transmitter, send a
page to Pager 9999 with the message “00_0000.”