Printer Commands
Chapter 5
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
470 Operators Manual
52
5.3.4 REAL-TIME CLOCK
^A
^D
Command
30
Change Clock: Use the sequence below to set the time and date of the optional
real-time socket:
^D30
5
HH:MM:SS
5
DD/MM/YY/W
5
HH
= hours (24 hour format)
MM
= month
MM
= minutes
DD
= day of month
SS
= seconds
YY
= last 2 digits of
year
W
= day of the week
1
= SUN
2
= MON
3
= TUE
4
= WED
5
= THR
6
= FRI
7
= SAT
The clock produces a string of text that is accessed through use of a TSN of 0
(See Table 10 for definitions of field parameters).
The text string is shown below...
HH:MM:SS MM/DD/YY XXX DD/MM/YY XXX
...where xxx is the day of the week.
These values should be inserted into the Field parameters for proper clock text access:
Clock Field Parameters
TSN
TSP
CC
TEXT
0
1
8
HH:MM:SS
0
10
8
MM/DD/YY
0
19
3
Day of Week
0
23
8
DD/MM/YY
0
32
3
Day of Week
Table 10