![Microcom 470 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/microcom/470/470_operators-manual_1786161053.webp)
Chapter 5
Printer Commands
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
470 Operators Manual
45
^A
^D
Command
22
Change SW2:
Software dip switch #2. Below is the ^AB sequence:
12345678
^ABxxxxxxxx
*******.)))),
******.)))),*
*****.)))),**
Power-up Label Format
*****
000=ROM Format File 1
*****
001=ROM or Non-Volatile User Format File 1
*****
010=ROM or Non-Volatile User Format File 2
*****
011=ROM or Non-Volatile User Format File 3
*****
100=ROM or Non-Volatile User Format File 4
*****
101=ROM or Non-Volatile User Format File 5
*****
110=ROM or Non-Volatile User Format File 6
*****
111=ROM or Non-Volatile User Format File 7
****.))))
1=Use Non-Volatile User Format File, 0=ROM
***.)))))
1=Print Button Enable, 0=Disable
**.))))))
1=Line Feed Button Disable, 0=Enable
*.)))))))
1=>RESTARTED< Response Enable, 0=Disable
.))))))))
1=Clear Text Enable, 0=Disable
Position:
1
Clear Text:
If enabled, all variable text will be erased when a ^D2
5
or ^B is
processed.
2
>RESTARTED< Response:
If the printer has been reset and this switch has
been enabled, the printer will respond to the first poll by sending the
>RESTARTED< message. If additional enquiries are made, the printer will
respond normally. The >RESTARTED< response is only issued once after
reset.
3
Line Feed Button:
Set to 1, the printer will not allow keypad use, even for paper
feed.
4
Print Button:
If this is 0, the 'PRINT' key acts like a Form Feed and printing will
occur. All other keypad functions respond normally.
5
Power-up Format Type:
This parameter determines whether to use a user
loadable non-volatile format file or a ROM format for the power-up label (defined
by positions 6, 7, and 8). See section 5.3.6 for more information on saving
format files in non-volatile memory. Please contact your service organization if
changes or additions need to be made to the ROM formats (i.e., the standard
power-up label).
6,7,8
Power-up Format Selection:
These switches decide which format to use as a
power-up label.