MicroAire ASP-1021 Скачать руководство пользователя страница 3

IM-LIPOTOWER Rev G

3

SYMBOL DEFINITIONS

   

 

TYPE B EQUIPMENT

 

ATTENTION SEE INSTRUCTIONS FOR USE

  

DO NOT LUBRICATE

 

 

 

DO NOT IMMERSE

 

 

ELECTROSTATIC SENSITIVE DEVICE

  h

 

PRODUCT CATALOG NUMBER

 

 

DO NOT REUSE

  M

 

MANUFACTURER

 

DATE OF MANUFACTURE (YYYY-MM)

  f

 

SERIAL NUMBER

 

RELATIVE HUMIDITY LIMITS

 

ATMOSPHERIC PRESSURE LIMITS

 

TEMPERATURE LIMITS

 

UL LISTING

INTRODUCTION

This document, MicroAire LipoTower System - Instructions For Use (IFU), is intended to describe the procedures 
required to safely operate, clean and maintain the REF ASP-1020, the REF ASP-1021.

The operation, maintenance, cleaning and sterilization procedures for the PAL-650 Power Assisted Lipoplasty 
Handpiece, the 1020/1025 Standard Electric Console and the 5020/5025 Electric Console are described in their 
respective IFUs.  This IFU addresses primarily the operation, maintenance cleaning and sterilization procedures 
applicable to the MicroAire LipoTower System.

The MicroAire LipoTower System can be configured to meet the requirements of an individual surgeon.  See SETUP 
section for details on system configuration.

WARNINGS / CAUTIONS / NOTES

Throughout this IFU, the following terms are used to identify operational hints as well as precautions that will help 
avoid accidental injury to patients or personnel, or to prevent damage to delicate powered instruments.

WARNING:

  

Used to indicate that the safety of patients and hospital personnel could be involved.

CAUTION:  

Used to point out special procedures or precautions that must be complied with to avoid  

 

 

 

damaging an instrument.

NOTE:    

Used to point out the easiest means of carrying out the techniques.

Содержание ASP-1021

Страница 1: ...MicroAire LipoTower System Instructions for Use...

Страница 2: ...nsole for PAL REF 5025 Electric Power Console for MicroAire Instruments REF PAL 1200 Liposuction Tubing 12 foot REF 1006 PALE PAL Instrument Cable for REF 1020 1025 REF 5006 PAL PAL Instrument Cable f...

Страница 3: ...nd the 5020 5025 Electric Console are described in their respective IFUs This IFU addresses primarily the operation maintenance cleaning and sterilization procedures applicable to the MicroAire LipoTo...

Страница 4: ...nd or postoperative hemodynamic stability and patient safety The capability of providing adequate timely replacement is essential for patient safety WARNING Grounding reliability can only be achieved...

Страница 5: ...system on another patient CAUTION Federal Law restricts this device to sale by or on the order of a physician or properly licensed practitioner CAUTION See PAL 650 Instrument System Instruction Manual...

Страница 6: ...CH ON allows pumps to be activated by the Control Switch STANDBY o turns vacuum pumps off 6 STORAGE BASKET 7 LOCKING CASTERS 8 PUSH HANDLE 9 MAIN VACUUM CONNECTION 10 REAR STORAGE BASKET 11 POWER INLE...

Страница 7: ...20 1025 or REF 5020 through the cable opening and connect it to the hospital grade outlet on the back of the cart Figure 6 4 Manuever the BNC cable from the REF 1020 1025 or REF 5020 through the cable...

Страница 8: ...er Rack on the top of the cart Slide one or more Waste Canister Rings REF ASP RNG 1200 or REF ASP RNG 2000 into any of the four available canister slots These slots also accept various wall mount styl...

Страница 9: ...or to use all system components should be inspected to detect any damage excessive wear corrosion or malfunction DO NOT use if any potential problems become apparent Contact MicroAire for resolution W...

Страница 10: ...PRESSURE ADJUSTMENT knob controls the amount of suction pressure Vacuum pressure is displayed on the LCD screen Suction is increased by turning the knob clockwise towards MAX and suction is decreased...

Страница 11: ...N OPTIONAL INSTALLING THE TUMESCENT MODULE 1 Turn off power and disconnect main power by unplugging power cord 2 Locate the Tumescent Bay cover on the left side of the cart Remove the the two retainin...

Страница 12: ...the foot switch still does not operate properly contact MicroAire Customer Service for additional troubleshooting and repair VACUUM PRESSURE IS INSUFFICIENT Ensure all aspiration canisters and aspira...

Страница 13: ...roAire LipoTower System is operated at high elevation or low atmospheric pressure aspiration performance may be adversely affected NOISE LEVEL EXPOSURE LIMITS The A weighted emission sound pressure le...

Страница 14: ...SUMMARY CAUTION The MicroAire LipoTower system needs to be installed and put into service according to the EMC information provided in this Instructions for Use manual Portable and mobile RF communica...

Страница 15: ...IM LIPOTOWER Rev G 15 Table 1 IEC 60601 1 2 Table 201 Table 2 IEC 60601 1 2 Table 202...

Страница 16: ...IM LIPOTOWER Rev G 16 Table 4 IEC 60601 1 2 Table 206 Table 3 IEC 60601 1 2 Table 204...

Страница 17: ...IM LIPOTOWER Rev G 17 NOTES...

Страница 18: ...IM LIPOTOWER Rev G 18 NOTES...

Страница 19: ...IM LIPOTOWER Rev G 19 NOTES...

Страница 20: ...nstruments LLC IM LIPOTOWER Rev G Printed in the USA M MicroAire Surgical Instruments LLC 3590 Grand Forks Blvd Charlottesville VA 22911 USA Telephone 800 722 0822 434 975 8000 Fax 800 648 4309 434 97...

Отзывы: