Special Calibration Settings - Page 3
1 2 3 4
1
2
3
4
MAXIMUM PULSE WIDTH
PWM ONLY
Location:
PAGE 3 - DISTANCE
Description:
In PWM Output, this adjusts value for
Maximum Pulse Width. This can be set from 0 to 100%
(This value must be larger that the Minimum Pulse
Width.)
Default:
90%
MINIMUM PULSE WIDTH
PWM ONLY
Location:
PAGE 3 - PRESSURE
Description:
In PWM Output, this adjusts value for
Minimum Pulse Width. This can be set from 0 to 100%
(This value must be smaller that the Maximum Pulse
Width.)
Default:
10%
PWM FREQUENCY -
PWM ONLY
Location:
PAGE 3 - AREA
Description:
In PWM Output, this adjusts value for PWM
Frequency. This can be set from 50 to 500Hz. Consult
your PWM device information for optimal frequency.
Default:
200
Hz.
PWM FREQUENCY
MAXIMUM PULSE WIDTH
MINIMUM PULSE WIDTH
—
MINIMUM PRESSURE
FIXED MINIMUM FLOW
PROPORTIONAL MINIMUM FLOW
RATE ALARM THRESHOLD
MINIMUM PRESSURE
Location:
PAGE 3 - VOLUME
Description:
When using pressure based control, this
sets an absolute minimum pressure for the system.
This parameter must be set, along with
Proportional
Minimum Flow
(below), for pressure based control to
function.
Default:
Off
FIXED MINIMUM FLOW
Location:
PAGE 3 - VOLUME/MIN.
Description:
Sets a fixed absolute minimum flow (gpm)
for the system. This ensures that the flow rate is
never less than the lowest range of the flowmeter -
preventing the flowmeter from stalling.
Default:
Off
PROPORTIONAL MINIMUM FLOW
Location:
PAGE 3 - TANK
Description:
Sets minimum flow value in Gallons/minute
for the system - proportional to the number of active
sections. This parameter must be set, along with
Minimum Pressure
(above), for pressure based control
to function.
Default:
Off
RATE ALARM THRESHOLD
Location:
PAGE 3 - RATE
Description:
Adjusts threshold value for the Rate Alarm
- can be set from 10-30%. This value is the percentage
of difference between the actual rate of application
and the intended (target) rate.
Default: 10%