Special Calibration Settings - Page 2
PRESSURE OFFSET
PRESSURE ALARM LOW
PRESSURE ALARM HIGH
PRESSURE FULL SCALE
1 2 3 4
1
2
3
4
PRESSURE OFFSET
Location:
PAGE 2 - AREA
Description:
Adjusts system to calculate pressure
readings when using an “Absolute” style pressure
sensor. Input Absolute Atmospheric Pressure in PSI
(bar) for your location.
Note: Leave at
0
when using optional Micro-Trak
pressure sensor(s) P/N 18757-18758, they are “gauge”
type sensors and self-adjust for ambient atmospheric
pressure.
Default:
0
PRESSURE ALARM LOW
Location:
PAGE 2 - DISTANCE
Description:
Enables and adjusts value for Pressure
Alarm - set value to notify operator when low level
is reached. This can be set to OFF (0) or up to 50% of
FULL SCALE setting. Parameter units: English = PSI,
Metric = bar.
Default:
Off
PRESSURE ALARM HIGH
Location:
PAGE 2 - PRESSURE
Description:
Enables and adjusts value for Pressure
Alarm - set value to notify operator when high level
is reached. This can be set to OFF (0) or up to 100%
of FULL SCALE setting. Parameter units: English = PSI,
Metric = bar.
Default:
Off
PRESSURE FULL SCALE
Location:
PAGE 2 - SPEED
Description:
Displays and adjusts FULL SCALE
(maximum) value for Pressure Sensor. Default setting
is 150 PSI for Micro-Trak Pressure Sensor P/N 18757.
Adjust it to 300 PSI for Micro-Trak P/N 18758.
NOTE: This measurement is always rated in PSI - even
if Metric units were specified in the UNITS Special
Calibration setting.
Default:
300
AUTO SHUTOFF -
STD ONLY
Location:
PAGE 2 - TANK
Description:
Enables Auto Shutoff feature - it runs the
control valve towards minimum flow each time HOLD
is selected, or when all (non-zero width) sections are
turned off, or when in AUTO and ground speed goes to
zero. Duration of Auto Shutoff feature is 18 seconds.
Default:
Off
MANUAL ENABLE
Location:
PAGE 2 - VOLUME
Description:
Enables (ON) or disables (OFF) Manual
Control mode. Disabling this function means the
console will only run in AUTO mode and the AUTO/
MAN switch will be inactive.
Default:
On
THREE-WAY VALVE ENABLE
Location:
PAGE 2 - VOLUME/MIN.
Description:
Enables the use of three-way Valves with
the SprayMate XRS system. This setting changes the
internal calculations for section totals so that flow in
return lines to the tank (or to hydraulic system) is not
included when sections are turned off.
Default:
Off
AGITATION PERCENTAGE -
PWM ONLY
Location:
PAGE 2 - RATE
Description:
In PWM Output, this enables Tank Agitation
when system is in Hold, and adjusts the desired duty
cycle for the agitation. This can be set to OFF (0)
or from 1 to 100%. Agitation is disabled during any
calibration mode.
Default:
Off
VALVE POLARITY -
STD ONLY
Location:
PAGE 2 - RATE
Description:
In STD Output, this defines operation of the
flow control valve - choose Bypass or Inline plumbing
configuration. See page 13 for illustration of Inline vs.
Bypass plumbing.
Default:
Inline
MANUAL ENABLE
THREE-WAY VALVE ENABLE
AUTO SHUTOFF
AGITATION/VALVE POLARITY
Setting Locations