Before operating the SprayMate™ XRS, it is necessary to calibrate it for the intended operation. The first step is choosing
intended UNITS (English or Metric) in Special Calibration, page 14 - this will also load default values.
CALIBRATION STEPS:
1.
Stop the vehicle, if moving.
2.
Switch console to HOLD, or turn all section switches OFF.
3.
Press and hold the Calibration button about 1 second until the ‘CAL’ icon appears on screen and Red LED light is
on.
4.
Select calibration position on rotary selector (see explanations of each position starting on page 10).
5.
Adjust values using Increase/Decrease buttons.
6.
To exit Calibration without saving changes - turn console OFF.
7.
To save changes and exit Calibration - press and hold the CAL button for 1 second - ‘CAL’ icon on screen will turn
off and red LED light will turn off.
NOTE:
When locked, Calibration settings can be viewed but not adjusted except for Target Rate and Row Width factors.
Press to enter or exit
calibration mode.
Press to increase or
decrease values.
Calibration
Indicates
Calibration Mode
Red LED indicates
Calibration Mode.
The example shown
here would set the
FLOW CAL
value to
calibrate the system
to the flowmeter.
Restoring Default Calibration Values
To restore
default calibration values and clear all counters (Tank, Volume, Area and Distance):
1.
Change the UNITS value in Special Calibration.
2.
Turn the rotary knob to a different calibration page.
3.
Turn the rotary knob back to UNITS.
4.
Reset UNITS value to original choice.